A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Simultaneous determination of cortisol and prednisolone in body fluids by using HPLC-DAD coupled with second-order calibration based on alternating trilinear decomposition. | LitMetric

Simultaneous determination of cortisol and prednisolone in body fluids by using HPLC-DAD coupled with second-order calibration based on alternating trilinear decomposition.

J Chromatogr B Analyt Technol Biomed Life Sci

State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, China.

Published: August 2006

A novel method for simultaneous determination of cortisol and prednisolone in body fluids has been developed in this paper. Three-way data recorded by high-performance liquid chromatography with a diode array detector (HPLC-DAD) have been analyzed by second-order calibration based on the alternating trilinear decomposition (ATLD) algorithm. The chemometric methodology selected exploits the second-order advantage of the three-way data arrays, which allows one to obtain concentrations of individual calibrated analytes even in the presence of interferences not present in the calibration samples (e.g. background in urine or plasma). It was applied to simultaneous determination of cortisol and prednisolone in both plasma and urine samples. Though the chromatographic and spectral peaks of the analytes were heavily overlapped and interferents coeluted with the compounds studied, good recoveries of the analytes could be obtained with HPLC-DAD coupled with second-order calibration based on ATLD. Sample preparation was based on solvent extraction (SE), and quantification can be carried out with simple mobile phase. The time required for the quantification process is shorter than other methods.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2006.04.043DOI Listing

Publication Analysis

Top Keywords

simultaneous determination
12
determination cortisol
12
cortisol prednisolone
12
second-order calibration
12
calibration based
12
prednisolone body
8
body fluids
8
hplc-dad coupled
8
coupled second-order
8
based alternating
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!