Objective: Several guidelines have been developed to direct the ordering of head computed tomography (CT) for patients, but most are clinical presentation-specific. Recently, an integrated guideline for ordering emergent head CT for patients who present to the ED of Western Hospital, Footscray, Victoria, Australia, was developed in response to concerns raised regarding perceived over-utilization of head CT for ED patients. Our aim was to determine compliance with the guideline.

Methods: This was an explicit retrospective medical record review of patients who presented to the ED of Western Hospital between 1/04/2004 and 17/6/2004 and had a head CT as part of their assessment. Clinical information for these cases was compared with guideline recommendations. Data are described by descriptive statistics.

Results: Of the 231 cases that were included in the study, 65 (28.1%, 95% confidence interval 23-35%) had abnormal CT findings. Guidelines were adhered to in 217 (93.9%, 95% confidence interval 91-97%) cases. For the cases where the guidelines were not adhered to (14; [6.1%]), there was only one abnormal scan the clinical significance of which is not clear.

Conclusion: The study found that compliance with head CT guideline was high. This suggests that the guideline is both clinically relevant and supported by ED doctors or conversely that the guideline is concordant with existing ordering practices of the ED.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1742-6723.2006.00846.xDOI Listing

Publication Analysis

Top Keywords

head computed
8
computed tomography
8
head patients
8
western hospital
8
95% confidence
8
confidence interval
8
guidelines adhered
8
head
6
guideline
5
guidelines
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!