Method for numerical simulation of two-term exponentially correlated colored noise.

Phys Rev E Stat Nonlin Soft Matter Phys

Physics Department, Middle East Technical University, 06531 Ankara, Turkey.

Published: April 2006

A method for numerical simulation of two-term exponentially correlated colored noise is proposed. The method is an extension of traditional method for one-term exponentially correlated colored noise. The validity of the algorithm is tested by comparing numerical simulations with analytical results in two physical applications.

Download full-text PDF

Source
http://dx.doi.org/10.1103/PhysRevE.73.046114DOI Listing

Publication Analysis

Top Keywords

exponentially correlated
12
correlated colored
12
colored noise
12
method numerical
8
numerical simulation
8
simulation two-term
8
two-term exponentially
8
method
4
noise method
4
noise proposed
4

Similar Publications

A data-driven framework for developing a unified density-modulus relationship for the human lumbar vertebral body.

J Mech Behav Biomed Mater

January 2025

Department of Mechanical Engineering, Boston University, Boston, MA 02215, USA; Center for Multiscale and Translational Mechanobiology, Boston University, Boston, MA 02215, USA; Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA.

Despite the broad agreement that bone stiffness is heavily dependent on the underlying bone density, there is no consensus on a unified relationship that applies to both cancellous and cortical compartments. Bone from the two compartments is generally assessed separately, and few mechanical test data are available for samples from the transitional regions between them. In this study, we present a data-driven framework integrating experimental testing and numerical modeling of the human lumbar vertebra through an energy balance criterion, to develop a unified density-modulus relationship across the entire vertebral body, without the necessity of differentiation between trabecular and cortical regions.

View Article and Find Full Text PDF

Purpose: Research has shown that prolonged endotracheal intubation can increase risk of aspiration following extubation. This study examined the relationship between swallowing and intubation among patients with COVID-19. We investigated the association between the duration of intubation and time until an oral diet was safely initiated and the correlation between the length of intubation and reduced sensation with aspiration as seen on flexible endoscopic evaluation of swallowing (FEES)/videofluoroscopic swallowing study (VFSS).

View Article and Find Full Text PDF

Purpose: To investigate the effect of average intraocular pressure (IOP) on the true rate of glaucoma progression (RoP) in the United Kingdom Glaucoma Treatment Study (UKGTS).

Methods: UKGTS participants were randomized to placebo or Latanoprost drops and monitored for up to two years with visual field tests (VF, 24-2 SITA standard), IOP measurements, and optic nerve imaging. We included eyes with at least three structural or functional assessments (VF with <15% false-positive errors).

View Article and Find Full Text PDF

When underground tunnels in coal mines traverse geological structurally abnormal zones (faults, collapse columns, fractured zones, etc.), excavation-induced unloading leads to instability and failure of the engineering rock mass. Rock masses in fractured zones are in elastic, plastic, and post-peak stress states, and the process of excavation through these zones essentially involves unloading under full stress paths.

View Article and Find Full Text PDF

Innovative double-emission carbon dots (DE-CDs) were synthesized via a one-step hydrothermal method using fennel and m-phenylenediamine (m-PD) as precursors. These DE-CDs exhibited dual emission wavelengths at 432 and 515 nm under different excitations, making them highly versatile for fluorescence-based applications. The fluorescence of the DE-CDs was efficiently quenched by tetracycline (TC) through the inner filter effect (IFE), allowing for the construction of a sensitive dual-response fluorescent sensor.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!