A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Does the acidity of self-etching primers affect bond strength and surface morphology of enamel? | LitMetric

Purpose: This study examined the ultrastructure and microtensile bond strengths (TBS) of self-etching (with different acidity) and conventional adhesive systems bonded to unground enamel.

Materials And Methods: Resin composite (Filtek Z250) buildups were bonded to unground enamel surfaces of third molars after adhesive application with the following materials: Clearfil SE Bond (CSE); Optibond Solo Plus Self-Etch (OP); Tyrian Self Priming Etching (TY), and the controls Scotchbond Multi-Purpose Plus (SBMP) and Single Bond (SB). Six teeth were assigned to each material. After storage in waterfor 24 h at 37 degrees C, the bonded specimens were sectioned into beams of approximately 0.8 mm2 and subsequently subjected to microTBS testing at a crosshead speed of 0.5 mm/min. The average values were subjected to one-way ANOVA (alpha = 0.05). The effect of surface conditioning of each material was observed under scanning electron microscopy (SEM).

Results: The highest resin-enamel bond strength was observed for SBMP (22.7 +/- 5.2) and SB (26.7 +/- 5.2 MPa). The lowest mean bond strengths were 10.9 +/- 3.2 and 7.8 +/- 1.5 MPa for TY and OP, respectively. CSE showed an intermediate performance (18.7 +/- 4.6 MPa). An overall increase in porosity was evident along the entire enamel surface treated with the self-etching primers; however, no selective demineralization similar to that with 35% phosphoric acid was observed.

Conclusion: The highest bond strength means and the more retentive etching pattern were observed for the two-step etch-and-rinse adhesives. Among the self-etching systems studied, Clearfil SE Bond should be preferred.

Download full-text PDF

Source

Publication Analysis

Top Keywords

bond strength
12
+/- mpa
12
self-etching primers
8
bond
8
bond strengths
8
bonded unground
8
clearfil bond
8
+/-
5
acidity self-etching
4
primers affect
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!