The purpose of this study was to compare the image quality of two-dimensional (2D) digital subtraction angiography (DSA) between a flat panel detector (FPD) of the direct conversion type with low radiation dose and a conventional image intensifier (I.I.)-TV system, and to assess 3D DSA with the FPD system in the depiction of intracranial vessels. Fifteen consecutive patients (five men, ten women; age range: 18-82 years; mean age: 55.5 years) were prospectively included in this study. All patients underwent 2D DSA with both the FPD and I.I.-TV system in one projection. The radiation doses during angiography were evaluated using a phantom. The 3D DSA images were created from the rotational DSA data with the FPD system. Two blinded radiologists independently evaluated 2D DSA with the FPD system and I.I.-TV system using a 5-point assessment scale (excellent to not visible) to assess the depiction of intracranial vessels. MIP and volume rendering (VR) images of 3D DSA with the FPD system were also evaluated using a 5-point scale (excellent to not visible). DSA and fluoroscopy dose measurements with the phantom showed a dose reduction of approximately 85% and 9% with the FPD system compared with the I.I.-TV system, respectively. For 2D DSA, the FPD system was significantly superior to the I.I.-TV system with respect to the visibility of the peripheral and perforating vessels (p<0.05). The peripheral and perforating vessels were also sufficiently visualized on MIP images of 3D DSA in all 15 cases. Our FPD system was found to be superior to the I.I.-TV system in visualizing small intracranial vessels combined with a significant reduction of radiation dose, and was able to create high-quality 3D DSA images on which high spatial resolution allowed precise visualization of small vessels such as perforating ones.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00330-006-0233-2 | DOI Listing |
China CDC Wkly
November 2024
National Center for AIDS/STD Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing, China.
Introduction: This study aimed to provide a comprehensive analysis of the human immunodeficiency virus (HIV) epidemiological landscape in China through a historical review and current assessment.
Methods: Data were extracted from China's HIV/AIDS Comprehensive Response Information Management System (CRIMS). Transmission patterns across different phases were visualized using stacked area charts.
BMC Pharmacol Toxicol
December 2024
Department of Anesthesiology, West China Hospital, Sichuan University, Chengdu, 610041, China.
Background: In the past few years, an increasing number of research studies have documented the utilization of durvalumab in the field of immunotherapy for cancerous tumors. However, there remains insufficient documentation regarding its associated adverse event (AEs). In order to enhance our comprehension of its toxicological profile, this investigation retrospectively examined the AEs linked to durvalumab using data from the US Food and Drug Administration adverse event reporting system (FAERS).
View Article and Find Full Text PDFMed Phys
December 2024
Research Center for Advanced Detection Materials and Medical Imaging Devices, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China.
Background: Recently, the popularity of dual-layer flat-panel detector (DL-FPD) based dual-energy cone-beam CT (CBCT) imaging has been increasing. However, the image quality of dual-energy CBCT remains constrained by the Compton scattered x-ray photons.
Purpose: The objective of this study is to develop a novel scatter correction method, named e-Grid, for DL-FPD based CBCT imaging.
Med Phys
November 2024
Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW, Australia.
Physiother Theory Pract
November 2024
Occupational Science and Occupational Therapy, Saint Louis University, Saint Louis, MO, USA.