The purpose of this study was to compare the image quality of two-dimensional (2D) digital subtraction angiography (DSA) between a flat panel detector (FPD) of the direct conversion type with low radiation dose and a conventional image intensifier (I.I.)-TV system, and to assess 3D DSA with the FPD system in the depiction of intracranial vessels. Fifteen consecutive patients (five men, ten women; age range: 18-82 years; mean age: 55.5 years) were prospectively included in this study. All patients underwent 2D DSA with both the FPD and I.I.-TV system in one projection. The radiation doses during angiography were evaluated using a phantom. The 3D DSA images were created from the rotational DSA data with the FPD system. Two blinded radiologists independently evaluated 2D DSA with the FPD system and I.I.-TV system using a 5-point assessment scale (excellent to not visible) to assess the depiction of intracranial vessels. MIP and volume rendering (VR) images of 3D DSA with the FPD system were also evaluated using a 5-point scale (excellent to not visible). DSA and fluoroscopy dose measurements with the phantom showed a dose reduction of approximately 85% and 9% with the FPD system compared with the I.I.-TV system, respectively. For 2D DSA, the FPD system was significantly superior to the I.I.-TV system with respect to the visibility of the peripheral and perforating vessels (p<0.05). The peripheral and perforating vessels were also sufficiently visualized on MIP images of 3D DSA in all 15 cases. Our FPD system was found to be superior to the I.I.-TV system in visualizing small intracranial vessels combined with a significant reduction of radiation dose, and was able to create high-quality 3D DSA images on which high spatial resolution allowed precise visualization of small vessels such as perforating ones.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00330-006-0233-2DOI Listing

Publication Analysis

Top Keywords

fpd system
24
ii-tv system
20
dsa fpd
20
system
11
dsa
9
dsa flat
8
flat panel
8
panel detector
8
direct conversion
8
conversion type
8

Similar Publications

Introduction: This study aimed to provide a comprehensive analysis of the human immunodeficiency virus (HIV) epidemiological landscape in China through a historical review and current assessment.

Methods: Data were extracted from China's HIV/AIDS Comprehensive Response Information Management System (CRIMS). Transmission patterns across different phases were visualized using stacked area charts.

View Article and Find Full Text PDF

Background: In the past few years, an increasing number of research studies have documented the utilization of durvalumab in the field of immunotherapy for cancerous tumors. However, there remains insufficient documentation regarding its associated adverse event (AEs). In order to enhance our comprehension of its toxicological profile, this investigation retrospectively examined the AEs linked to durvalumab using data from the US Food and Drug Administration adverse event reporting system (FAERS).

View Article and Find Full Text PDF

Model-based CBCT scatter correction with dual-layer flat-panel detector.

Med Phys

December 2024

Research Center for Advanced Detection Materials and Medical Imaging Devices, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China.

Background: Recently, the popularity of dual-layer flat-panel detector (DL-FPD) based dual-energy cone-beam CT (CBCT) imaging has been increasing. However, the image quality of dual-energy CBCT remains constrained by the Compton scattered x-ray photons.

Purpose: The objective of this study is to develop a novel scatter correction method, named e-Grid, for DL-FPD based CBCT imaging.

View Article and Find Full Text PDF
Article Synopsis
  • The study explores the development of a linac-mounted photon-counting detector (PCD) for image-guided radiotherapy (IGRT) that could significantly enhance imaging by improving soft-tissue contrast and spatial resolution compared to traditional flat panel detectors (FPDs).
  • Researchers characterized the image quality of the PCD, focusing on parameters like 2D spatial resolution, noise, and contrast, by comparing it with an FPD using various imaging techniques and calibration methods.
  • Results showed that the PCD provides a linear energy calibration and better raw contrast in images, suggesting its potential for improved tumor delineation in radiation therapy applications.
View Article and Find Full Text PDF
Article Synopsis
  • - The study examines how the presentation of Amyotrophic Lateral Sclerosis (ALS) varies across different stages and phenotypes, utilizing movement system diagnoses (MSD) to inform care strategies.
  • - Four patients from an ALS clinic were assessed over nine years, highlighting differences in disability and mobility based on their specific ALS characteristics, such as bulbar or limb onset.
  • - Findings suggest that understanding the interplay between MSD and ALS phenotype can improve clinical decisions and treatment approaches for managing the disease effectively.
View Article and Find Full Text PDF