Spatiotemporal tuning of rapid interactions between visual-motion analysis and reaching movement.

J Neurosci

NTT Communication Science Laboratories, Nippon Telegraph and Telephone Corporation, Atsugi, Kanagawa 243-0198, Japan.

Published: May 2006

In addition to the goal-directed preplanned control, which strongly governs reaching movements, another type of control mechanism is suggested by recent findings that arm movements are rapidly entrained by surrounding visual motion. It remains, however, controversial whether this rapid manual response is generated in a goal-oriented manner similarly to preplanned control or is reflexively and directly induced by visual motion. To investigate the sensorimotor process underlying rapid manual responses induced by large-field visual motion, we examined the effects of contrast and spatiotemporal frequency of the visual-motion stimulus. The manual response amplitude increased steeply with image contrast up to 10% and leveled off thereafter. Regardless of the spatial frequency, the response amplitude increased almost proportionally to the logarithm of stimulus speed until the temporal frequency reached 15-20 Hz and then fell off. The maximum response was obtained at the lowest spatial frequency we examined (0.05 cycles/degrees). These stimulus specificities are surprisingly similar to those of the reflexive ocular-following response induced by visual motion, although there is no direct motor entrainment from the ocular to manual responses. In addition, the spatiotemporal tuning is clearly different from that of perceptual effects caused by visual motion. These comparisons suggest that the rapid manual response is generated by a reflexive sensorimotor mechanism. This mechanism shares a distinctive visual-motion processing stage with the reflexive control for other motor systems yet is distinct from visual-motion perception.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6675296PMC
http://dx.doi.org/10.1523/JNEUROSCI.0340-06.2006DOI Listing

Publication Analysis

Top Keywords

visual motion
20
rapid manual
12
manual response
12
spatiotemporal tuning
8
preplanned control
8
response generated
8
induced visual
8
manual responses
8
response amplitude
8
amplitude increased
8

Similar Publications

People with amblyopia show deficits in global motion perception, especially at slow speeds. These observers are also known to have unstable fixation when viewing stationary fixation targets, relative to healthy controls. It is possible that poor fixation stability during motion viewing interferes with the fidelity of the input to motion-sensitive neurons in visual cortex.

View Article and Find Full Text PDF

Quantitative and Visual Benefits of Data-Driven Motion Correction on Oncologic PET/CT: A Prospective Cross-sectional Study.

Acad Radiol

January 2025

Department of Radiology, Washington University School of Medicine, 510 S. Kingshighway Blvd, St. Louis, MO 63110 (S.I., M.A.T., M.I., C.S., R.L., A.H., R.L.W., T.J.F.). Electronic address:

Rationale And Objective: Conventional positron emission tomography (PET) respiratory gating utilizes a fraction of acquired PET counts (i.e., optimal gate [OG]), whereas elastic motion correction with deblurring (EMCD) utilizes all PET counts to reconstruct motion-corrected images without increasing image noise.

View Article and Find Full Text PDF

Background: There has been an increase in both primary anatomic (aTSA) and reverse total shoulder arthroplasty (rTSA) over the last decade, with rates peaking for patients aged 75 years and older. Despite aTSA being the mainstay of treatment for patients with glenohumeral arthritis in the absence of rotator cuff insufficiency, there has been an upward trend of rTSA utilization in the elderly due to concerns about rotator cuff integrity, regardless of deformity. The purpose of this study is to evaluate outcomes including pain, function, range of motion, satisfaction, and complications in patients 80 years or older following primary anatomic and reverse total shoulder arthroplasty for osteoarthritis without full thickness rotator cuff tears.

View Article and Find Full Text PDF

Purpose: Blood loss and pain management are significant concerns in total knee arthroplasty (TKA). Tranexamic acid (TA) and cryotherapy have been used separately to address these issues, but their comparative effectiveness is not well studied. This study aimed to evaluate the efficacy of intravenous TA and cryotherapy in reducing blood loss and improving clinical outcomes after TKA.

View Article and Find Full Text PDF

Background: Calcaneal fracture malunion (CFM) commonly occurs with multiple pathologic changes and progressive pain and difficulty walking. The purpose of this study was to propose a modified 3-plane joint-preserving osteotomy for the treatment of CFM with subtalar joint incongruence, and to compare its efficacy to subtalar arthrodesis.

Methods: A retrospective comparative analysis of the data of 56 patients with CFM admitted from January 2017 to December 2022 was performed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!