A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Blood screening of benzodiazepines and tricyclic antidepressants. Results of 5 years of interhospital controls]. | LitMetric

[Blood screening of benzodiazepines and tricyclic antidepressants. Results of 5 years of interhospital controls].

Acta Clin Belg

Laboratoire des Urgences Biochimiques et Toxicologiques, Centre hospitalier Lyon Sud, 165 chemin du grand Revoyet, 69495 Pierre-benite, France.

Published: October 2006

Pro bio Qual Association of Lyon have proposed a control which include the control for detecting benzodiazepines (BZD) and tricyclic antidepressants (ADT) since 2000. With this control, we have evaluated the specificity and the sensitivity of techniques used. We have tested the maprotiline reactivity too (tetracyclic antidepressant). We report results achieved with different immunoassay methods and their performances: specificity and sensitivity. The number of laboratories which realize these analyses is constant: these laboratories are hospital laboratories. Two methods are most common used: the fluorescence polarization immunoassay (FPIA) and the enzyme multiplied immunoassay test (EMIT). The evolution of these techniques does square with the evolution of chemistry analysers used in hospital laboratories. For the BZD, the specificity is good. For the ADT, carbamazepine at low concentration (5 mg/L) gives a positive result with FPIA Abbott assay; carbamazepine at high concentration (25 mg/L) gives a negative result with EMIT assay; phenothiazines give a positive response. For the BZD, the analyser Integra gives best results of sensitivity. Results of sensitivity obtained with the kit EMIT DAU are better than results obtained with the kit EMIT Serum. For the ADT, results of sensitivity obtained with FPIA Abbott assay seem better; the adaptation of EMIT assay on Integra analyser gives less good results. The reactivity for the BZD is very different: we can ignore a severe intoxication with alprazolam or lorazepam (response << cut off) but we can give a positive result for a therapeutic concentration of diazepam for example. With ADT, we haven't the same problem. But the reactivity for nortriptyline is less good than the reactivity for amitriptyline. So we should use a "cut off" concentration which corresponds to the best sensitivity and the best specificity.

Download full-text PDF

Source
http://dx.doi.org/10.1179/acb.2006.062DOI Listing

Publication Analysis

Top Keywords

tricyclic antidepressants
8
specificity sensitivity
8
hospital laboratories
8
concentration mg/l
8
fpia abbott
8
abbott assay
8
emit assay
8
kit emit
8
sensitivity
5
emit
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!