AI Article Synopsis

  • The study aimed to evaluate the effectiveness of a low-weight polypropylene mesh with an absorbable coating for vaginal prolapse surgery through a multicentre approach involving 230 patients.
  • After a minimum follow-up of 10 months for 143 patients, 92.3% were reported as anatomically cured, with low recurrence rates of prolapse and manageable complications like vaginal erosions.
  • Significant improvements in quality of life and symptoms were recorded, demonstrating that this surgical approach may reduce complications while effectively treating genital prolapse.

Article Abstract

The aim of this study was to evaluate the anatomical and functional results of a low-weight polypropylene mesh coated with an absorbable film in prolapse surgery by vaginal route. We have conducted a prospective multicentre study in 13 gynaecological and urological units. There were 230 patients requiring repair for anterior or posterior vaginal prolapse included. The present report is based on the analysis of the first 143 patients evaluated after at least 10 months follow-up. All patients were operated by the vaginal route using a specially designed mesh (Ugytex, Sofradim, France). Prolapse severity were evaluated using the Pelvic Organ Prolapse staging system. Symptoms and quality of life were evaluated preoperatively and during follow-up using the validated Pelvic Floor Distress Inventory (PFDI) and Pelvic Floor Impact Questionnaire (PFIQ) self-questionnaires. Mean age was 63 years (37-91). Anterior, posterior and anterior-posterior repair with the mesh were performed in 67 (46.9%), 11 (7.7%) and 65 (45.4%) patients, respectively. With a mean follow-up of 13 months (10-19), 132 patients were considered anatomically cured (92.3%) with a recurrence rate of 9 of 132 for cystocele (6.8%) and 2 of 76 for rectocele (2.6%). Nine vaginal erosions occurred (6.3%), six of them necessitated another procedure by simple excision. The rate of de novo dyspareunia was 12.8%. At follow-up, improvement of PFDI and PFIQ scores were highly significant (p<0.0001). The use of low-weight polypropylene mesh coated with a hydrophilic absorbable film for vaginal repair of genital prolapse seems to decrease local morbidity while maintaining low recurrence rates.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00192-006-0135-5DOI Listing

Publication Analysis

Top Keywords

vaginal route
12
low-weight polypropylene
8
polypropylene mesh
8
prospective multicentre
8
multicentre study
8
anterior posterior
8
pelvic floor
8
prolapse
5
vaginal
5
patients
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!