A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Dynamic measurement of accommodation and pupil size using the portable Grand Seiko FR-5000 autorefractor. | LitMetric

Dynamic measurement of accommodation and pupil size using the portable Grand Seiko FR-5000 autorefractor.

Optom Vis Sci

Ophthalmic Research Group, Life and Health Sciences, Aston University, Birmingham, United Kingdom.

Published: May 2006

Purpose: The purpose of this study was to evaluate the potential of the portable Grand Seiko FR-5000 autorefractor to allow objective, continuous, open-field measurement of accommodation and pupil size for the investigation of the visual response to real-world environments and changes in the optical components of the eye.

Methods: The FR-5000 projects a pair of infrared horizontal and vertical lines on either side of fixation, analyzing the separation of the bars in the reflected image. The measurement bars were turned on permanently and the video output of the FR-5000 fed into a PC for real-time analysis. The calibration between infrared bar separation and the refractive error was assessed over a range of 10.0 D with a model eye. Tolerance to longitudinal instrument head shift was investigated over a +/-15 mm range and to eye alignment away from the visual axis over eccentricities up to 25.0 degrees . The minimum pupil size for measurement was determined with a model eye.

Results: The separation of the measurement bars changed linearly (r2 = 0.99), allowing continuous online analysis of the refractive state at 60 Hz temporal and approximately 0.01 D system resolution with pupils >2 mm. The pupil edge could be analyzed on the diagonal axes at the same rate with a system resolution of approximately 0.05 mm. The measurement of accommodation and pupil size were affected by eccentricity of viewing and instrument focusing inaccuracies.

Conclusions: The small size of the instrument together with its resolution and temporal properties and ability to measure through a 2 mm pupil make it useful for the measurement of dynamic accommodation and pupil responses in confined environments, although good eye alignment is important.

Download full-text PDF

Source
http://dx.doi.org/10.1097/01.opx.0000216059.54932.3aDOI Listing

Publication Analysis

Top Keywords

accommodation pupil
16
pupil size
16
measurement accommodation
12
portable grand
8
grand seiko
8
seiko fr-5000
8
fr-5000 autorefractor
8
measurement bars
8
eye alignment
8
system resolution
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!