The first synchrotron radiation beamline using a 4 m-long undulator at the 12 GeV storage ring PETRA delivers hard X-ray photons usable up to 300 keV. The photon intensity is measured on an absolute scale in the energy range between 16 and 60 keV and compared with calculated intensities. The experimental set-up described is also used to measure the horizontal and vertical emittance of the source.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1107/S0909049596010734 | DOI Listing |
J Environ Manage
January 2025
School of Environment and Safety Engineering, Qingdao University of Science Technology, Qingdao, 266042, China.
As one of the top emitters of methane (CH), China must take action to achieve its carbon neutrality goal. Programs to reduce CH emissions would benefit from the establishment of the China Certified Emission Reduction (CCER) trading market. However, studies investigating the impact of the CCER trading market on CH reduction remain limited.
View Article and Find Full Text PDFRev Sci Instrum
January 2025
National Key Laboratory of Science and Technology on Advanced Laser and High Power Microwave, Institute of Applied Electronics, China Academy of Engineering Physics, Mianyang 621900, China.
The Chinese Academy of Engineering Physics Terahertz Free Electron Laser Facility (CAEP THz FEL, CTFEL) has been operated as a user facility for over five years. To further meet the growing demands of modern science, an upgrade project for an infrared-terahertz free electron laser facility based on CTFEL has been proposed to broaden the frequency range from 0.1-4.
View Article and Find Full Text PDFACS Appl Mater Interfaces
January 2025
Anhui Huasun Energy Company, Limited, Xuancheng 242000, China.
A rear emitter with a p-type boron-doped hydrogenated amorphous silicon/nanocrystalline silicon [a-Si:H(p)/nc-Si:H(p)] stack was prepared for the silicon heterojunction (SHJ) solar cell to improve its short-circuit current density (). CO plasma treatment (CO PT) was applied to a-Si:H(p) to facilitate the crystallization of the subsequently deposited nc-Si:H(p). To evaluate the effect of the CO PT, two different nc-Si:H(p) layers with low and high crystallinity (χ) were investigated.
View Article and Find Full Text PDFNucl Med Biol
January 2025
Nuclear Physics Institute of the Czech Academy of Sciences, Řež, Czech Republic.
Limited availability constrains the implementation of Ac, the most promising α emitter for targeted therapy, in clinical practice. Proton activation of Ra is one of few realistic solutions to this problem. We have therefore measured cross sections of relevant Ra(p,xn) nuclear reactions in the energy range of 12.
View Article and Find Full Text PDFEJNMMI Radiopharm Chem
January 2025
Department of Nuclear Medicine and Medical Physics, Karolinska University Hospital, Stockholm, 171 76, Sweden.
Background: Beyond the use of conventional short-lived PET radionuclides, there is a growing interest in tracking larger biomolecules and exploring radiotheranostic applications. One promising option for imaging medium-sized molecules and peptides is ⁵⁵Co (T₁/₂ = 17.5 h, β⁺ = 76%), which enables imaging of new and already established tracers with blood circulation of several hours.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!