Measurements of emittance and absolute spectral flux of the PETRA undulator at DESY Hamburg.

J Synchrotron Radiat

Hamburger Synchrotronstrahlungslabor HAS YLAB at Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, Hamburg D-22607, Germany.

Published: January 1997

The first synchrotron radiation beamline using a 4 m-long undulator at the 12 GeV storage ring PETRA delivers hard X-ray photons usable up to 300 keV. The photon intensity is measured on an absolute scale in the energy range between 16 and 60 keV and compared with calculated intensities. The experimental set-up described is also used to measure the horizontal and vertical emittance of the source.

Download full-text PDF

Source
http://dx.doi.org/10.1107/S0909049596010734DOI Listing

Publication Analysis

Top Keywords

measurements emittance
4
emittance absolute
4
absolute spectral
4
spectral flux
4
flux petra
4
petra undulator
4
undulator desy
4
desy hamburg
4
hamburg synchrotron
4
synchrotron radiation
4

Similar Publications

As one of the top emitters of methane (CH), China must take action to achieve its carbon neutrality goal. Programs to reduce CH emissions would benefit from the establishment of the China Certified Emission Reduction (CCER) trading market. However, studies investigating the impact of the CCER trading market on CH reduction remain limited.

View Article and Find Full Text PDF

Characterization of the upgraded photoinjector at the Chinese Academy of Engineering Physics Terahertz Free Electron Laser Facility.

Rev Sci Instrum

January 2025

National Key Laboratory of Science and Technology on Advanced Laser and High Power Microwave, Institute of Applied Electronics, China Academy of Engineering Physics, Mianyang 621900, China.

The Chinese Academy of Engineering Physics Terahertz Free Electron Laser Facility (CAEP THz FEL, CTFEL) has been operated as a user facility for over five years. To further meet the growing demands of modern science, an upgrade project for an infrared-terahertz free electron laser facility based on CTFEL has been proposed to broaden the frequency range from 0.1-4.

View Article and Find Full Text PDF

A rear emitter with a p-type boron-doped hydrogenated amorphous silicon/nanocrystalline silicon [a-Si:H(p)/nc-Si:H(p)] stack was prepared for the silicon heterojunction (SHJ) solar cell to improve its short-circuit current density (). CO plasma treatment (CO PT) was applied to a-Si:H(p) to facilitate the crystallization of the subsequently deposited nc-Si:H(p). To evaluate the effect of the CO PT, two different nc-Si:H(p) layers with low and high crystallinity (χ) were investigated.

View Article and Find Full Text PDF

Limited availability constrains the implementation of Ac, the most promising α emitter for targeted therapy, in clinical practice. Proton activation of Ra is one of few realistic solutions to this problem. We have therefore measured cross sections of relevant Ra(p,xn) nuclear reactions in the energy range of 12.

View Article and Find Full Text PDF

Rapid fabrication and dissolution of pressed Ni/Mg matrix targets for Co production.

EJNMMI Radiopharm Chem

January 2025

Department of Nuclear Medicine and Medical Physics, Karolinska University Hospital, Stockholm, 171 76, Sweden.

Background: Beyond the use of conventional short-lived PET radionuclides, there is a growing interest in tracking larger biomolecules and exploring radiotheranostic applications. One promising option for imaging medium-sized molecules and peptides is ⁵⁵Co (T₁/₂ = 17.5 h, β⁺ = 76%), which enables imaging of new and already established tracers with blood circulation of several hours.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!