Objectives: This study sought to compare tissue Doppler imaging (TDI) with velocity-encoded (VE) magnetic resonance imaging (MRI) for left ventricular (LV) dyssynchrony assessment.
Background: Cardiac resynchronization therapy (CRT) is proposed for patients with heart failure, depressed LV function, and a wide QRS complex. Selection is based mainly on electrocardiogram criteria, but recent data suggest that intraventricular dyssynchrony may be preferred for selection. An LV dyssynchrony can adequately be assessed with TDI, but this has not been compared directly with other imaging modalities. A VE MRI potentially allows direct myocardial wall motion measurements similar to TDI.
Methods: Twenty patients with heart failure, systolic LV dysfunction, and a wide QRS complex were included, as well as 10 normal individuals with normal QRS duration and LV function. The TDI and VE MRI data were acquired to study intraventricular dyssynchrony.
Results: Left ventricular dyssynchrony was not observed in normal individuals (mean dyssynchrony -2 +/- 15 ms on TDI; mean -5 +/- 17 ms on MRI, p = NS). In patients, mean LV dyssynchrony was 55 +/- 37 ms on TDI; 49 +/- 38 ms on MRI (p = NS). Good correlation between both modalities was observed (linear regression TDI = 0.99 x MRI - 5, n = 30, r = 0.98, p < 0.01). The MRI showed a small, nonsignificant underestimation of 5 +/- 8 ms compared with TDI. Agreement between MRI and TDI for classification according to severity of LV dyssynchrony (minimal, intermediate, and extensive) was excellent (kappa +/- SE = 0.96 +/- 0.07, p < 0.01) with 95% of patients classified identical.
Conclusions: Both MRI and TDI yield comparable information on LV dyssynchrony; MRI is useful in the selection of patients for CRT.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jacc.2006.01.058 | DOI Listing |
Ultrasound J
January 2025
Health Sciences North Research Institute, Sudbury, ON, Canada.
The duration of mechanical systole-also termed the flow time (FT) or left ventricular ejection time (LVET)-is measured by Doppler ultrasound and increasingly used as a stroke volume (SV) surrogate to guide patient care. Nevertheless, confusion exists as to the determinants of FT and a critical evaluation of this measure is needed. Using Doppler ultrasound of the left ventricular outflow tract velocity time integral (LVOT VTI) as well as strain and strain rate echocardiography as grounding principles, this brief commentary offers a model for the independent influences of FT.
View Article and Find Full Text PDFInt J Legal Med
January 2025
Institute for Legal Medicine, Faculty of Medicine, Saarland University, Campus Homburg, Building 49.1, Kirrberger Straße 100, 66421, Homburg/Saar, Germany.
Aortic regurgitation is a common valve disease and can be caused by delineated findings such as fenestrations or hardly discernible alterations of the aortic root geometry. Therefore, aortic regurgitation can be a challenging diagnosis during an autopsy. Cardiac surgeons, however, are confronted with comparable problems during surgery and have developed a refined knowledge of the anatomy of the aortic root including its geometry.
View Article and Find Full Text PDFEur Heart J Cardiovasc Imaging
January 2025
Department of Cardiovascular Medicine, Gunma University Graduate School of Medicine, Maebashi, Gunma, Japan.
Aims: Left ventricular (LV) diastolic dysfunction and heart failure with preserved ejection fraction (HFpEF) are common cardiac complications of patients with systemic sclerosis (SSc). Exercise stress echocardiography is often used in symptomatic patients with SSc to detect abnormal increases in pulmonary pressures during exercise, but the pathophysiologic and prognostic significance of exercise stress echocardiography to assess the presence of HFpEF in these patients is unclear.
Methods And Results: Patients with SSc (n=140) underwent ergometry exercise stress echocardiography with simultaneous expired gas analysis.
Artif Organs
January 2025
Division of Cardiology, Department of Medicine, Columbia University College of Physicians and Surgeons and NewYork-Presbyterian Hospital, New York, New York, USA.
Background: GLP-1 RAs improve cardiometabolic outcomes in obese, diabetic, and heart failure patients. Data on the safety and efficacy of GLP-1 RA in advanced heart failure with durable LVAD is limited.
Objectives: To assess the safety and efficacy of GLP-1 RA in durable LVAD patients.
J Vet Intern Med
January 2025
Boehringer Ingelheim Pharma GmbH & Co., Ingelheim, Germany.
Background: Myxomatous mitral valve disease (MMVD) is frequently diagnosed in small breed dogs. Pimobendan oral solution has been developed to improve dosing accuracy in small and toy breed dogs.
Hypothesis/objectives: Demonstrate bioequivalence of pimobendan oral solution with pimobendan chewable tablets using a pharmacokinetic and a pharmacodynamic study in healthy purpose bred dogs.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!