Translational and rotational pupil tracking by use of wavefront aberration data and image registration techniques.

Opt Lett

Henry Wellcome Laboratories for Vision Science, Department of Optometry and Visual Science, City University, London, UK.

Published: June 2006

We present a methodology with which to evaluate translations and rotations of wavefront aberration measurements of systems in which the exit pupil suffers displacements and rotations with respect to the reference frame of the measuring device. We propose to use image registration techniques to account for rotations, translations, and scale changes of the pupil. We present a proof of principle, using an artificial eye in addition to computer simulations. The method is software based and requires no additional hardware.

Download full-text PDF

Source
http://dx.doi.org/10.1364/ol.31.001642DOI Listing

Publication Analysis

Top Keywords

wavefront aberration
8
image registration
8
registration techniques
8
translational rotational
4
rotational pupil
4
pupil tracking
4
tracking wavefront
4
aberration data
4
data image
4
techniques methodology
4

Similar Publications

Significance: Visual acuity (VA) depends on many factors. When the goal is to assess retinal health rather than performance, then using a 3-mm pupil reduces unwanted wavefront aberrations. The axis of astigmatism can still potentially change with age.

View Article and Find Full Text PDF

Regulating the proportion of low-order aberrations within total aberrations can effectively alter the tilt-to-length (TTL) coupling noise in a space gravitational wave telescope. Nevertheless, the low-order aberration ratio is disrupted during the actual manufacturing of the telescope. To address this issue, we analyzed the impacts of wavefront errors and low-order aberration proportions on the TTL coupling noise, determined the design requirements, and designed a 400 mm-aperture space gravitational wave telescope optical system.

View Article and Find Full Text PDF

Due to their advantages of compact geometries and lightweight, diffractive optical elements (DOEs) are attractive in various applications such as sensing, imaging and holographic display. When designing DOEs based on algorithms, a diffraction model is required to trace the diffracted light propagation and to predict the performance. To have more precise diffraction field tracing and optical performance simulation, different diffraction models have been proposed and developed.

View Article and Find Full Text PDF

Adaptive optics (AO) improves the spatial resolution of microscopy by correcting optical aberrations. While its application has been well established in microscopy modalities utilizing a circular pupil, its adaptation to systems with non-circular pupils, such as Bessel-focus two-photon fluorescence microscopy (2PFM) with an annular pupil, remains relatively uncharted. Herein, we present a modal focal AO (MFAO) method for Bessel-focus 2PFM.

View Article and Find Full Text PDF

In space-based gravitational wave detection, establishing ultra-long-distance and ultra-high-precision laser links between satellites is achieved through the laser acquisition and tracking system. The laser spot centroid positioning method, which offers low computational complexity and strong adaptability to beam shape, is currently the core measurement method during the laser acquisition phase. However, due to various interference factors encountered in practical tests, this algorithm often falls short of meeting the extremely high requirements.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!