A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Experimental characterization of APS undulator A at high photon energies (50-200 keV). | LitMetric

Experimental characterization of APS undulator A at high photon energies (50-200 keV).

J Synchrotron Radiat

Advanced Photon Source, Argonne National Laboratory, Argonne, IL 60439, USA.

Published: March 1998

The considerable intensity of Advanced Photon Source (APS) undulator A as a source of high-energy X-rays permits the performance of numerous types of experiments that require such photon energies. Measured and calculated properties, in the 50-200 keV range, of the X-ray beam from undulator A, installed in sector 1 of the APS, are presented. The flux spectra observed at various gaps agree well with calculations that incorporate the actual magnetic field within the device and the emittance and energy spread of the stored positrons. The field errors and energy spread cause the X-ray beam to lose undulator radiation properties at high energies, as seen in the smeared-out spectral harmonics and increased beam divergence, giving resemblance to a low-K wiggler source. Owing to the wiggler-like behavior in this photon-energy range, the optimal operating condition for undulator A is in the vicinity of the closed-gap setting, corresponding to a maximum critical energy.

Download full-text PDF

Source
http://dx.doi.org/10.1107/S090904959701368XDOI Listing

Publication Analysis

Top Keywords

aps undulator
8
photon energies
8
50-200 kev
8
x-ray beam
8
energy spread
8
undulator
5
experimental characterization
4
characterization aps
4
undulator high
4
high photon
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!