Inter-frame motion correction for MR thermometry.

Med Image Comput Comput Assist Interv

Quantitative Imaging, Delft University of Technology, 2628 CJ Delft, The Netherlands.

Published: June 2006

Noninvasive temperature measurement is feasible with MRI to monitor changes in thermal therapy. Phase shift based MR thermometry gives an estimate of the relative temperature variation between thermal and baseline images. This technique is limited, however, when applied on targets under inter-frame motion. Simple image registration and subtraction are not adequate to recover the temperature properly since the phase shift due to temperature changes is corrupted by an unwanted phase shift. In this work, the unwanted phase shift is predicted from the raw registered phase shift map itself. To estimate the unwanted phase shift, a thin plate smoothing spline is fitted to the values outside the heated region. The spline value in the heated area serves as an estimate for the offset. The estimation result is applied to correct errors in the temperature maps of an ex-vivo experiment.

Download full-text PDF

Source
http://dx.doi.org/10.1007/11566465_72DOI Listing

Publication Analysis

Top Keywords

phase shift
24
unwanted phase
12
inter-frame motion
8
phase
6
shift
6
temperature
5
motion correction
4
correction thermometry
4
thermometry noninvasive
4
noninvasive temperature
4

Similar Publications

One-step high-pressure and high-temperature direct aqueous mineral carbonation of tailings derived from mining of Platinum Group Metals in South Africa requires a fundamental understanding of the reactivity of the most dominant mineral phases, i.e. pyroxene and plagioclase (66 wt.

View Article and Find Full Text PDF

This study investigates the relationship between SARS-CoV-2 RT-PCR cycle threshold (Ct) values and key COVID-19 transmission and outcome metrics across five years of the pandemic in Jalisco, Mexico. Utilizing a comprehensive time-series analysis, we evaluated weekly median Ct values as proxies for viral load and their temporal associations with positivity rates, reproduction numbers (Rt), hospitalizations, and mortality. Cross-correlation and lagged regression analyses revealed significant lead-lag relationships, with declining Ct values consistently preceding surges in positivity rates and hospitalizations, particularly during the early phases of the pandemic.

View Article and Find Full Text PDF

SARS-CoV-2, the virus responsible for COVID-19, has undergone significant genetic evolution since its emergence in 2019. This study examines the genomic diversity of SARS-CoV-2 in Brazil after the worst phase of the pandemic, the wider adoption of routine vaccination, and the abolishment of other non-pharmacological preventive measures from July 2022 to July 2024 using 55,951 sequences retrieved from the GISAID database. The analysis focuses on the correlation between confirmed COVID-19 cases, sequencing efforts across Brazilian states, and the distribution and evolution of viral lineages.

View Article and Find Full Text PDF

Channeled Polarimetry for Magnetic Field/Current Detection.

Sensors (Basel)

January 2025

Institute of Optical Materials and Technologies, Bulgarian Academy of Sciences, 109, Acad. G. Bonchev Str., 1113 Sofia, Bulgaria.

Magneto-optical magnetic field/current sensors are based on the Faraday effect, which involves changing the polarized state of light. Polarimetric methods are therefore used for measuring polarization characteristics. Channeled polarimetry allows polarization information to be obtained from the analysis of the spectral domain.

View Article and Find Full Text PDF

Fiber Bragg gratings (FBGs) inscribed by UV light and different femtosecond laser techniques (phase mask, point-by-point, and plane-by-plane) were exposed-in several irradiation cycles-to accumulated high doses of gamma rays (up to 124 MGy) and neutron fluence (8.7 × 10/cm) in a research-grade nuclear reactor. The FBG peak wavelengths were measured continuously in order to monitor radiation-induced shifts.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!