A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Multidetector CT angiography using a dual-head power injector and bolus tracking for the diagnosis of aortic aneurysms at reduced contrast material dosage. | LitMetric

Rationale And Objectives: To establish the utility of multidetector computed tomography (CT) angiography using dual-head power injector in the diagnosis of aortic diseases.

Methods: In a prospective study, 151 patients with aortic diseases were examined by four-detector CT. Scanning was performed using bolus tracking technique. In all patients nonionic contrast was injected at the rate of 1.5 mL/sec. One hundred one patients were examined with dual-head power injector using 0.6 mL/kg contrast flushed by 30 mL of saline solution (group D). Fifty patients were examined with single-head power injector using 1.0 mL/kg contrast only (group S). We evaluated CT values at descending aorta, upper abdominal aorta, abdominal aortic bifurcation, and bilateral common femoral arteries.

Results: There were no statistically significant difference of CT values at descending aorta, upper abdominal aorta, abdominal aortic bifurcation, and right common femoral artery. At left common femoral artery, CT values in group D were higher than those in group S with statistically difference (P < .05). In group D, about 40% dose reduction was achieved without reducing image qualities.

Conclusion: Multidetector CT angiography using dual-head power injector was valuable for the contrast dose reduction of aortic diseases.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.acra.2006.03.003DOI Listing

Publication Analysis

Top Keywords

power injector
20
dual-head power
16
angiography dual-head
12
common femoral
12
multidetector angiography
8
bolus tracking
8
diagnosis aortic
8
aortic diseases
8
patients examined
8
injector ml/kg
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!