A temperature-jump design for conventional NMR probes.

J Magn Reson

Department of Chemistry, Division of Physical Chemistry and Industrial NMR Center, Royal Institute of Technology, SE-10044 Stockholm, Sweden.

Published: July 2006

The design and performance of a simple probe insert for temperature-jump experiments in conventional NMR probes is described. The insert uses the output from conventional NMR amplifiers for heating conductive aqueous samples with a rate of 30-80 K/s for 200 W radiofrequency power. The observed dependence of the heating rate on sample conductivity is explained by the dominance of dielectric heating. Factors governing the temperature gradient within the sample are discussed.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmr.2006.04.006DOI Listing

Publication Analysis

Top Keywords

conventional nmr
12
nmr probes
8
temperature-jump design
4
design conventional
4
probes design
4
design performance
4
performance simple
4
simple probe
4
probe insert
4
insert temperature-jump
4

Similar Publications

Cardiac MR image reconstruction using cascaded hybrid dual domain deep learning framework.

PLoS One

January 2025

Medical Image Processing Research Group (MIPRG), Dept. of Elect. & Comp. Engineering, COMSATS University Islamabad, Islamabad, Pakistan.

Recovering diagnostic-quality cardiac MR images from highly under-sampled data is a current research focus, particularly in addressing cardiac and respiratory motion. Techniques such as Compressed Sensing (CS) and Parallel Imaging (pMRI) have been proposed to accelerate MRI data acquisition and improve image quality. However, these methods have limitations in high spatial-resolution applications, often resulting in blurring or residual artifacts.

View Article and Find Full Text PDF

Unconventional Imaging Methods in Psoriatic Arthritis.

Curr Rheumatol Rep

January 2025

Department of Rheumatology and Clinical Immunology, Charité - Universitätsmedizin Berlin, Berlin, Germany.

Purpose Of Review: Psoriatic arthritis (PsA) is a complex heterogeneous inflammatory disease that affects about one-third of patients with psoriasis. PsA leads to significant physical impairment and reduced quality of life. Therefore, early diagnosis and intervention are critical for improving long-term outcomes.

View Article and Find Full Text PDF

Right ventricular (RV) dysfunction after biventricular repair is critical in most adults with congenital heart disease (ACHD). Conventional 2D magnetic resonance imaging (MRI) measurement is considered as a 'gold standard' for RV evaluation; however, addition information on ACHD after biventricular repair is sometimes required. The reasons why adjunctive information is required is as follows: (I) to evaluate the severity of cardiac burden in symptomatic patients with normal RV size and ejection fraction (EF), (II) to determine the optimal timing of invasive treatments in asymptomatic ones, and (III) to detect proactively a potential cardiac burden leading to ventricular deterioration, from a fluid dynamics perspective.

View Article and Find Full Text PDF

To investigate the value of preoperative MRI features and ADC histogram analysis for evaluating tumor-infiltrating CD8+ T cells in meningiomas. In this single-center cross-sectional study, we conducted a retrospective analysis of clinical, imaging, and pathological data from 84 patients with meningioma and performed immunohistochemical staining to quantitatively evaluate CD8+ T cells. Using X-Tile software, we divided the patients into high-and low-CD8+ T cells groups based on cut-off values.

View Article and Find Full Text PDF

Background: In uterine cervical cancer (UCC), tumour staging is performed according to the 2018 International Federation of Gynecology and Obstetrics (FIGO) system, where imaging is incorporated, or the more generic Tumour Node Metastasis (TNM) classification. With the technical development in diagnostic imaging, continuous prospective evaluation of the different imaging methods contributing to stage determination is warranted. The aims of this interim study were to (1) evaluate the performance of radiological FIGO (rFIGO) and T staging (rT) with 2-fluorine-18-fluoro-deoxy-glucose (2[18F]-FDG)-positron emission tomography with computed tomography (PET/CT) and with magnetic resonance imaging (PET/MRI), compared to clinical FIGO (cFIGO) and T (cT) staging based on clinical examination and conventional imaging, in treatment-naïve UCC, and to (2) identify possible MRI biomarkers for early treatment response after radiotherapy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!