Background: We sought to compare the efficacy of a monopolar radiofrequency ablation system in vivo near the portal vein and the hepatic veins in porcine liver.

Materials And Methods: Radiofrequency ablation of healthy livers near the portal vein and the hepatic veins was performed in 10 pigs with a multitined expandable electrode. Volumes and diameters of zones of ablation were assessed by magnetic resonance imaging.

Results: Volumes (16.0 +/- 5.5 mL, P = 0.001) and diameters (4.0 +/- 0.7 cm, 3.3 +/- 0.7 cm, 3.0 +/- 0.6 cm, P
Conclusions: Higher energy deposition is needed to ablate liver tissue near the portal vein than near the hepatic veins. As a result, the zone of ablation is larger near the hepatic vein than near the portal vein.