A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Influence of the spectrophotometric detection mode on the separation performance of systems with monolithic capillary columns: on-column and external-cell detection modes. | LitMetric

Poly(butyl methacrylate) monolithic columns were prepared by thermally initiated radical polymerization in fused-silica capillaries of 320 microm i.d. The prepared monolithic columns were tested by capillary liquid chromatography (CLC) combined with a UV-VIS spectrophotometric detector. The influence of the detection configuration (i.e., on-column and external-cell detection modes) on the performance of the chromatographic system was investigated. In the on-column detection mode within the monolith, the detection window was located inside the column section filled with the monolith. With the on-column detection configuration after the monolith, the detection window was positioned just behind the column section containing the monolith. Using the external-cell detection mode, an additional detection capillary, provided with a detection window defining the external-cell, was connected to the monolithic capillary column. These detection modes were critically compared in terms of the principal chromatographic parameters of the system involving the prepared monolithic capillary columns.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2006.04.002DOI Listing

Publication Analysis

Top Keywords

detection
12
detection mode
12
monolithic capillary
12
external-cell detection
12
detection modes
12
detection window
12
capillary columns
8
on-column external-cell
8
monolithic columns
8
prepared monolithic
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!