A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Prospective 3-year surveillance for nosocomial and environmental Legionella pneumophila: implications for infection control. | LitMetric

Objectives: To perform a 3-year, prospective surveillance program for legionnaires disease (LD) in a large university hospital in Rome, and to assess the usefulness of the hospital water monitoring program in predicting the risk of nosocomial LD.

Methods: Samples from patients with new cases of nosocomial pneumonia were sent for legionella laboratory investigations. Meanwhile, water samples for bacteriological analysis were collected every 6 months from high- and medium-risk hospital wards (10 in total). Legionella pneumophila isolates collected were serotyped and analyzed by pulsed-field gel electrophoresis.

Results: From June 2001 through May 2004, the pneumonia surveillance identified one case of nosocomial LD among 43 cases of nosocomial pneumonia (2.3%). Environmental investigations detected L. pneumophila in 12 (18.7%) of the 64 water samples, of which 50% belonged to serogroup 1. The L. pneumophila count and the percentage of positive locations never exceeded 10(2) colony-forming units/L and 20%, respectively, except when the LD nosocomial case occurred (positive water samples, 40%; L. pneumophila count, <10(2) colony-forming units/L). Genotyping showed 3 prevalent clones of L. pneumophila in the water distribution network, of which one persisted over the 3 years. One clone contained 3 different L. pneumophila serogroups (2, 4, and 6).

Conclusions: The low incidence of nosocomial cases of LD appears to be associated with a low percentage (<20%) of positive water samples per semester and with a low contamination level (<10(2) colony-forming units/L). An infection control system for nosocomial LD should, therefore, be based on both environmental and clinical surveillance, together with the appropriate maintenance of the hospital water distribution system.

Download full-text PDF

Source
http://dx.doi.org/10.1086/503642DOI Listing

Publication Analysis

Top Keywords

water samples
12
legionella pneumophila
8
cases nosocomial
8
nosocomial pneumonia
8
pneumophila count
8
nosocomial
6
pneumophila
5
prospective 3-year
4
3-year surveillance
4
surveillance nosocomial
4