A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Gel Electrophoresis of Chloroplast Polypeptides: Comparison of One-Dimensional and Two-Dimensional Gel Analyses of Chloroplast Polypeptides From Euglena gracilis. | LitMetric

Euglena chloroplast polypeptides are resolved by an adaptation of the two-dimensional gel electrophoretic technique of O'Farrell (1975 J Biol Chem 250: 4007-4021). The present results are compared with those obtained by our earlier two-dimensional gel analyses as well as those obtained by one-dimensional gel analyses. Up to 75 micrograms of Euglena chloroplast polypeptides are resolved on one-dimensional sodium dodecylsulfate linear gradient 7.5 to 15% polyacrylamide gels into 43 stained polypeptide bands compared to only 33 bands resolved on a similar gel containing only 10% polyacrylamide. In contrast, two-dimensional gel electrophoresis (isoelectric focusing for the first dimension, sodium dodecylsulfate gel electrophoresis for the second dimension) further improves the resolution of the chloroplast polypeptides and especially so when a linear gradient gel is used for the second dimension. Delipidation of Euglena chloroplasts with acetone-ether and subsequent solubilization of polypeptides with Triton X-100 followed by sonication are all necessary for successful resolution of chloroplast polypeptides on two-dimensional gels. Up to 300 micrograms of chloroplast polypeptides can be clearly resolved into 56 to 59 stainable spots by the present two-dimensional gel technique when a linear gradient gel is used for the second dimension. Thus, about 30% of the polypeptide bands on a one-dimensional gel are separated into multiple polypeptides on a two-dimensional gel. The use of two-dimensional gels to separate labeled polypeptides with subsequent detection of labeled spots by autoradiography or fluorography again improves the resolution of the chloroplast polypeptides. For example, when (35)S-labeled chloroplast polypeptides are separated by the present two-dimensional gel technique with a linear gradient polyacrylamide gel in the second dimension, autoradiography or fluorography detects over 80 individual polypeptide spots. This is about twice the number resolved by our previous analyses which used a 10% polyacrylamide gel in the second dimension. Polypeptides detected range in molecular weight from about 8.5 to about 145 kilodaltons with apparent isoelectric points from pH 4.5 to 8.0. Fluorography provides rapid detection of labeled polypeptides and is 10 times more sensitive than autoradiography.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC425744PMC
http://dx.doi.org/10.1104/pp.67.4.623DOI Listing

Publication Analysis

Top Keywords

chloroplast polypeptides
36
two-dimensional gel
28
second dimension
20
gel
16
linear gradient
16
gel second
16
polypeptides
14
gel electrophoresis
12
gel analyses
12
resolution chloroplast
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!