A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Determination of glutathione in hemolysed erythrocyte with amperometric sensor based on TTF-TCNQ. | LitMetric

Determination of glutathione in hemolysed erythrocyte with amperometric sensor based on TTF-TCNQ.

Clin Chim Acta

Instituto de Química-UNICAMP, Departamento de Química Analítica. P.O. Box 6154, 13083-970 Campinas-SP, Brazil.

Published: September 2006

Background: GSH has a relevant role in human metabolism as an indicator of disease risks. An amperometric sensor for glutathione (GSH) determination is described as an alternative method featuring simple construction procedure and short time analysis.

Method: The developed sensor was used to determine glutathione at low potential using a TTF-TCNQ complex.

Results: The sensor exhibits a linear response range from 5 to 340 micromol/l under applied potential of 200 mV vs. SCE. The sensitivity and detection limit were 90.1 microA l/mmol cm(2) and 0.3 micromol/l, respectively.

Conclusion: When the sensor was tested in hemolysed erythrocyte samples for GSH determination, a good correlation in results was observed between the sensor and the spectrophotometric method. The sensor showed recovery values between 98% and 102%.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cca.2006.03.006DOI Listing

Publication Analysis

Top Keywords

hemolysed erythrocyte
8
amperometric sensor
8
gsh determination
8
sensor
7
determination glutathione
4
glutathione hemolysed
4
erythrocyte amperometric
4
sensor based
4
based ttf-tcnq
4
ttf-tcnq background
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!