There has been a recent trend towards using a raft of small diameter 3.5mm cortical screws for supporting depressed tibial plateau fractures (Schatzker type III). Our aim was to compare the biomechanical properties of a raft of 3.5 mm cortical screws with that of 6.5 mm cancellous screws in a synthetic bone model. Ten rigid polyurethane foam (sawbone) blocks, with a density simulating osteoporotic bone and ten blocks with a density simulating normal density bone were obtained. A Schatzker type III fracture was created in each block. The fracture fragments were then elevated and supported using two 6.5 mm cancellous screws in ten blocks and four 3.5 mm cortical screws in the remaining. The fractures were loaded using a Lloyd testing machine. The mean force needed to produce a depression of 5 mm was 700.8 N with the four-screw construct and 512.4 N with the two-screw construct in the osteoporotic model. This difference was highly statistically significant (p = 0.009). The mean force required to produce the same depression was 1878.2 N with the two-screw construct and 1938.2 N with the four-screw construct in the non-osteoporotic model. Though the difference was not statistically significant (p = 0.42), an increased fragmentation of the synthetic bone fragments was noticed with the two-screw construct but not with the four-screw construct. A raft of four 3.5 mm cortical screws is biomechanically stronger than two 6.5 mm cancellous screws in resisting axial compression in osteoporotic bone.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.knee.2006.03.003 | DOI Listing |
BMC Surg
January 2025
Department of Hand and Foot Surgery, Shandong Provincial Hospital, Shandong First Medical University, Jinan, China.
The deltoid ligament (medial collateral ligament) and the syndesmosis (a composite ligamentous structure at the distal tibiofibular junction) are critical for maintaining ankle stability. In cases of high-energy ankle fractures, these structures are often injured simultaneously, leading to instability and potential long-term complications such as post-traumatic arthritis. This review aims to explore advancements in minimally invasive techniques for the treatment of combined deltoid ligament and syndesmosis injuries, with a focus on optimizing surgical outcomes and reducing patient morbidity.
View Article and Find Full Text PDFJ Dent Sci
January 2025
Department of Physical Therapy and Assistive Technology, National Yang Ming Chiao Tung University, Taipei, Taiwan.
Background/purpose: The use of finite element (FE) analysis in implant biomechanics offers many advantages over other approaches in simulating the complexity of clinical situations. The aim of this study was to perform an optimization analysis of dental implants with different thread designs in three types of bone quality.
Materials And Methods: The three-dimensional FE model of a mandibular bone block with a screw-shaped dental implant and superstructure was simulated.
J Dent Sci
January 2025
School of Dentistry, China Medical University, Taichung, Taiwan.
Background/purpose: Studies have indicated that 50%-55% of the population have malocclusion, and approximately 5%-10% require orthognathic surgery to correct this condition. Optimal placement of plates and screws significantly affects the success rate of the surgery and postoperative stability. This study evaluates the cortical thickness of the maxillary bone in the nasomaxillary and zygomaticomaxillary buttress regions in Taiwanese patients based on cone-beam computed tomography (CBCT) images.
View Article and Find Full Text PDFShoulder Elbow
January 2025
Department of Shoulder & Elbow, Orthopedic Institute, Sioux Falls, SD, USA.
Background: Distal biceps tendon rupture is an injury that causes a significant reduction in strength and endurance. Combined cortical button and interference screw fixation has been utilized via single-incision technique. There are limited data describing this technique utilizing a double-incision approach.
View Article and Find Full Text PDFInjury
January 2025
Department of Orthopaedic Surgery, Cedars - Sinai Medical Center, Los Angeles, CA, USA. Electronic address:
Objectives: The purpose of this study is to determine what demographic and anatomical variables affect successful placement of a superior medullary ramus screw, and how they affect the maximal diameter of that screw.
Methods: Design: Prognostic Level IV SETTING: Level I Trauma Center Patients/Participants: Two hundred consecutive patients underwent computed tomography (CT) of the pelvis. We included those patients aged 18 and older without osseous injury or abnormalities precluding measurement.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!