Background: The present study aimed to evaluate the diagnostic accuracy of four-slice computed tomography for the detection, localization and patency assessment of metal coronary stents in a general population referred for coronary angiography late after coronary angioplasty.

Methods: Twenty-four consecutive patients with 34 coronary stents underwent multislice computed tomography within 24 h before a clinically driven coronary angiography performed 245 +/- 92 days after coronary stent implantation. For each patient, two independent operators were asked to evaluate the overall number of stents, the treated coronary vessels and segments, the presence of side-branches in the stented segment, the vessel patency, and the presence of binary in-stent restenosis.

Results: Four-slice computed tomography was feasible in 23 out of 24 patients (96%). Diagnostic accuracy was 94% for stent detection, 96% for the recognition of the stented coronary vessel and 97% for the identification of the stented segment. Accuracy in detection of side-branches in the stented segment, vessel patency and in-stent restenosis was 86%, 88% and 50%, respectively.

Conclusions: Four-slice computed tomography is accurate in the identification of the stented coronary vessel and segment. By contrast, accuracy is low in the detection of vessel patency and in-stent restenosis. Such a technique does not appear to be useful as a screening tool before invasive diagnostic procedures.

Download full-text PDF

Source
http://dx.doi.org/10.2459/01.JCM.0000223254.24309.b3DOI Listing

Publication Analysis

Top Keywords

computed tomography
20
four-slice computed
16
coronary angiography
12
coronary stents
12
stented segment
12
vessel patency
12
coronary
11
diagnostic accuracy
8
side-branches stented
8
segment vessel
8

Similar Publications

Enhancing Diagnostic Accuracy of Lung Nodules in Chest Computed Tomography Using Artificial Intelligence: Retrospective Analysis.

J Med Internet Res

January 2025

Department of Health Policy and Management, Bloomberg School of Public Health, Johns Hopkins University, Baltimore, MD, United States.

Background: Uncertainty in the diagnosis of lung nodules is a challenge for both patients and physicians. Artificial intelligence (AI) systems are increasingly being integrated into medical imaging to assist diagnostic procedures. However, the accuracy of AI systems in identifying and measuring lung nodules on chest computed tomography (CT) scans remains unclear, which requires further evaluation.

View Article and Find Full Text PDF

The current study aimed to objectively evaluate the fit of a rectangular, tapered stem to the severely dysplastic hips on the basis of the proximal femoral anatomy and the dimensional properties of the stem. It was hypothesized that the stem size planned with accordance to the diaphyseal canal width alone can accommodate the distal femur successfully with no sizing mismatch. Forty-six patients (53 hips) suffering from secondary osteoarthritis due to hip dysplasia scheduled for total hip arthroplasty (THA) with a subtrochanteric transverse shortening osteotomy were included.

View Article and Find Full Text PDF

Prediction of hip fracture by high-resolution peripheral quantitative computed tomography in older Swedish women.

J Bone Miner Res

January 2025

Sahlgrenska Osteoporosis Centre, Department of Internal Medicine and Clinical Nutrition, Institute of Medicine, University of Gothenburg, Gothenburg, Sweden.

The socioeconomic burden of hip fractures, the most severe osteoporotic fracture outcome, is increasing and the current clinical risk assessment lacks sensitivity. This study aimed to develop a method for improved prediction of hip fracture by incorporating measurements of bone microstructure and composition derived from high-resolution peripheral quantitative computed tomography (HR-pQCT). In a prospective cohort study of 3028 community-dwelling women aged 75 to 80, all participants answered questionnaires and underwent baseline examinations of anthropometrics and bone by dual x-ray absorptiometry (DXA) and HR-pQCT.

View Article and Find Full Text PDF

In 2019, the novel coronavirus swept the world, exposing the monitoring and early warning problems of the medical system. Computer-aided diagnosis models based on deep learning have good universality and can well alleviate these problems. However, traditional image processing methods may lead to high false positive rates, which is unacceptable in disease monitoring and early warning.

View Article and Find Full Text PDF

: The main aim of this paper was to perform the morphological assessment of children's mandibles of different etiology of dys-functions within the temporomandibular joint, from isolated idiopathic ankylosis to craniofacial malformations co-existing with genetic disorders. : The investigations encompassed seven patients at the age of 0-3. Measurements were conducted on the basis of data obtained from computed tomography.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!