Purpose: To evaluate aortic diameter outcomes after stent-graft implantation for aortic dissection in the descending thoracic aorta.
Methods: Fifty patients with type A dissection after ascending aortic surgery (n = 10), type B dissection (n = 34), or intramural hematoma (n = 6) underwent stent-graft repair in 3 centers. Thrombosis and aortic diameter were analyzed by computed tomographic angiography at different levels of the aorta before stent-graft implantation, at discharge, and at follow-up. Measurements were standardized.
Results: In all, 67 stent-grafts were implanted for acute (n = 18) and chronic (n = 32) dissection. Stent-graft placement was successfully performed with high technical success (100%) despite 4 major complications (iliac thrombosis in 2 cases, aortic rupture, and a type A dissection) in 3 (6%) patients. Complete thrombosis of the thoracic false lumen was observed in 42% and 63% of cases at discharge and at follow-up (mean 15 months), respectively. At follow-up, the diameters of the entire aorta (mean 5 mm, p < 0.05) and the false lumen (mean 11 mm, p < 0.0001) decreased. Diameters of the abdominal aorta remained stable in association with persistent false lumen perfusion at this level. Aortic diameter results were better in the subgroup of patients with intramural hematoma compared to patients with Marfan syndrome. Three early deaths unrelated to the stent-graft procedure occurred; 2 patients with partial thrombosis of the false lumen died in follow-up secondary to aortic diameter growth.
Conclusion: Complete thrombosis of the false lumen by stent-graft coverage of the entry tear results in decreased diameter of the entire aorta. In patients with partial thrombosis of the false lumen, the aneurysm continues to enlarge.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1583/04-1416R.1 | DOI Listing |
Ann Thorac Surg Short Rep
September 2023
Department of Cardiovascular Surgery, Iwate Prefectural Central Hospital, Morioka, Iwate, Japan.
Background: A strategy combining tear-oriented initial surgical procedure and subsequent thoracic endovascular aortic repair (TEVAR) can be adopted for acute type A aortic dissection (ATAAD). This study investigated this strategy's outcomes and the role of the aortic hiatus (AH).
Methods: Overall, 192 consecutive patients with ATAAD who underwent initial surgery between 2012 and 2021 were assessed in this observational retrospective study.
Ann Thorac Surg Short Rep
December 2024
Division of Cardiac Surgery, Inova Heart and Vascular Institute, Inova Health Systems, Falls Church, Virginia.
Background: DeBakey type I aortic dissections (AD) are most frequently treated with hemiarch repair. A subset of patients demonstrates persistent distal end-organ ischemia secondary to persistent true lumen (TL) compression. We describe the use of bare metal stent grafting across the residual arch dissection with the Zenith Dissection Endovascular Stent (ZDES, Cook Medical) in 7 patients with type I AD that was repaired in a hemiarch configuration with a compromised distal TL and organ malperfusion.
View Article and Find Full Text PDFAnn Thorac Surg Short Rep
June 2024
Department of Cardiovascular Surgery, Fukushima Medical University, Fukushima, Japan.
Background: There is limited experience and knowledge of the use of the fenestrated frozen elephant trunk (FET) technique in acute type A aortic dissection (ATAAD). This study's aims were to assess the clinical outcomes of the fenestrated FET technique for ATAAD and to identify its best practices and pitfalls.
Methods: This study included 101 patients who underwent emergency surgical aortic repair for ATAAD at our hospital between October 2018 and April 2023.
Vascular
January 2025
Division of Vascular Surgery, Medical University of South Carolina, Charleston, SC, USA.
Objectives: Mal-deployment of the thoracic endovascular aortic repair (TEVAR) stent graft during a frozen elephant trunk (FET) procedure for an acute type A aortic dissection (ATAAD) leads to devastating complications. We report a hemiarch replacement with TEVAR stent graft covering the aortic arch vessels salvaged through an endovascular approach.
Methods: A 69-year-old man with ATAAD in 2018, status post-hemiarch repair with TEVAR, presented in 2023 with progressive dizziness/syncope and lower extremity hypertension with inability to tolerate anti-hypertensives.
Cureus
December 2024
Department of Neurosurgery, Hirosaki University Graduate School of Medicine, Hirosaki, JPN.
Tandem occlusion due to acute cervical carotid artery dissection should be promptly treated with thrombectomy for reperfusion. If the cervical lesion has reached severe stenosis or complete occlusion, balloon angioplasty and, in certain cases, carotid artery stenting should be performed before thrombectomy for the intracranial lesion. Angioplasty or stent placement is performed in the true lumen, but securing the placement is challenging when the true lumen cannot be determined.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!