Restriction landmark genome scanning (RLGS) is a 2-DE of genomic DNA, which visualizes thousands of loci. In a conventional RLGS method for methylation analysis, we have used a methylation sensitive restriction enzyme, NotI as a landmark. However, it was unable to discriminate methylation polymorphism from sequence polymorphism. Here, we report an improved RLGS method to detect methylated sites directly. We employed isoschizomers, MspI and HpaII, that recognize the same sequence (CCGG) but have different methylation sensitivity. We carried out the RLGS analysis of Arabidopsis thaliana ecotype Columbia, and obtained a pair of spot patterns with MspI and HpaII. We detected 22 spots in both patterns. In comparison of them, 18% of the spots were polymorphic, which indicated the methylation of C(5m)CGG sites. Further analyses revealed an additional methylated site of NotI. Moreover, 52 and 54 restriction enzyme sites were also analyzed in two other ecotypes, Wassilewskija and Landsberg erecta, respectively. Consequently, 15% of the 52 common sites showed methylation polymorphism among the three ecotypes. The restriction sites analyzed in this study were located in or near genes, and contribute new data about the correlation between methylation status and gene expression. Therefore, this result strongly indicates that the improved RLGS method is readily applicable to practical analyses of methylation dynamics, and provides clues to the relationship between methylation and gene expression.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/elps.200500776 | DOI Listing |
Micromachines (Basel)
October 2022
Department of Optoelectronic Engineering, College of Advanced Interdisciplinary Studies, National University of Defense Technology, Changsha 410073, China.
Because of the non-orthogonal configuration of multi-sensors, the redundant inertial navigation system (INS) has a more complex error model compared with the traditional orthogonal INS, and the complexity of sensors configuration also increases the difficulty of error separation. Based on sufficient analysis of the error principle of redundant IMUs, a generalized high-accuracy calibration modeling method which is suitable for filtering method systematic calibration is summarized in this paper, and it has been applied to an RIMU prototype consisting of four ring laser gyros (RLGs) and four quartz accelerometers. Through the rotational excitation of the three-axis turntable in the laboratory, the high-precision filtering method systematic calibration of the RIMU is achieved, and static navigation and dynamic vehicle test experiments are also carried out.
View Article and Find Full Text PDFInt J Surg
October 2022
Division of HBP Surgery and Liver Transplantation, Department of Surgery, Korea University College of Medicine, Seoul, Republic of Korea. Electronic address:
Background: Adult-to-adult living donor liver transplantation (LDLT) is a notable type of liver transplantation. Several centers prefer the right liver graft (RLG) over the left liver graft (LLG) for better recovery of recipients. We compared the outcomes of donors and recipients between LDLT using LLGs and RLGs.
View Article and Find Full Text PDFDevices as large as ring laser gyroscopes (RLGs) for fundamental physics and geophysics investigation are currently run by means of radio frequency (RF) power supply systems. This is not the standard method to supply a gas laser, which typically is powered by a DC system. In literature, RF power supply lasers were studied several years ago, and to correctly understand the behavior of devices such as RLGs, a more detailed study has been pursued.
View Article and Find Full Text PDFSensors (Basel)
January 2020
Department of Precision Instruments, school of Mechanical and Instrumental Engineering, Xi'an University of Technology, Xi'an 710048, Shaanxi, China.
In a high accuracy strapdown inertial navigation system (SINS), the ring laser gyroscope's (RLG) bias changes and the performance decreases due to factors in the RLG's self-heating and changes in ambient temperature. Therefore, it is important to study the bias temperature drift characteristics of RLGs in high, low, and variable temperature environments. In this paper, a composite temperature calibration scheme is proposed.
View Article and Find Full Text PDFSensors (Basel)
December 2019
Huazhong Institute of Electro-Optics, Wuhan National Laboratory for Optoelectronics, Wuhan 430223, China.
The mechanical dithered ring laser gyro (RLG) effectively overcomes the lock-in effect and ensures the sensitive accuracy of the low angular rate for the gyro. However, in the inertial measurement unit (IMU) system, the dither excitation of three RLGs causes the coupled vibration of the IMU structure, which could seriously limit the measuring accuracy of RLGs. In this paper, the vibration frequency response characteristic of laser gyro IMU is taken as the focus point, and the method of multi-rigid body dynamics is used to establish the dynamic model of IMU suitable for vibration frequency response analysis.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!