Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3928/01477447-20060401-09 | DOI Listing |
Acta Parasitol
January 2025
Laboratory of Morpho-Molecular Integration and Technologies, Federal Rural University of the Amazon (UFRA), Belém, State of Pará, Brazil.
Purpose: This work described a new species of Ceratomyxa, based on morphological and phylogenetic analyzes of myxospores collected from the gallbladder of the fish Astyanax mexicanus.
Methods: Sixty-two specimens were captured, between December 2022 and February 2024, in the Flexal River, in the community of Tessalônica, state of Amapá. The specimens were transported alive to the Laboratory of Morphophysiology and Animal Health, at the State University of Amapá, where the studies were carried out.
J Pharm Sci
January 2025
Drug Delivery and Disposition, KU Leuven, Department of Pharmaceutical and Pharmacological Sciences, Campus Gasthuisberg ON2, Herestraat 49 b921, 3000 Leuven, Belgium. Electronic address:
In order to evaluate the stability of an amorphous solid dispersion (ASD) it is crucial to be able to accurately determine whether the ASD components are homogeneously mixed or not. Several solid-state analysis techniques are at the disposal of the formulation scientist, such as for example modulated differential scanning calorimetry (mDSC) and solid-state nuclear magnetic resonance spectroscopy (ssNMR). ssNMR is a robust, versatile, and accurate analysis technique with a large number of application possibilities.
View Article and Find Full Text PDFJ Knee Surg
January 2025
Orthopaedic Surgery, Hamamatsu University School of Medicine, Hamamatsu, Japan.
Introduction: We aimed to assess medial meniscal (MM) healing and horizontal tear (HT) repair in the knees of young patients.
Materials And Methods: We enrolled 37 knees of 35 patients (mean age: 28.0 ± 10.
Biomed Phys Eng Express
January 2025
Children's Hospital of Eastern Switzerland, Claudiusstrasse 6, St.Gallen, 9006, SWITZERLAND.
Mapping the myomagnetic field of a straight and easily accessible muscle after electrical stimulation using triaxial optically pumped magnetometers (OPMs) to assess potential benefits for magnetomyography (MMG). Approach: Six triaxial OPMs were arranged in two rows with three sensors each along the abductor digiti minimi (ADM) muscle. The upper row of sensors was inclined by 45° with respect to the lower row and all sensors were aligned closely to the skin surface without direct contact.
View Article and Find Full Text PDFBiomed Phys Eng Express
January 2025
Physics and Applied Mathematics, Pakistan Institute of Engineering and Applied Sciences, Qau, Islamabad, Islamabad, 44000, PAKISTAN.
The current study investigated the geometry, design and solid angle impacts on full energy peak efficiency (FEPE) of NaI(Tl) detectors for a line source. A line source is fabricated using 99mTc solution filled in a borosilicate glass tube of inner diameter 3 mm, tube wall thickness 2.5 mm and length 12.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!