Three pulse photon echo peak shift spectroscopy and transient grating measurements on Zn-substituted cytochrome c, Zn-tetraphenylporphyrin, and Zn-protoporphyrin IX are reported. The effects of protein conformation, axial ligation, and solvent are investigated. Numerical simulations of the peak shift and transient grating experiments are presented. The simulations employed recently derived optical response functions for square-symmetric molecules with doubly degenerate excited states. Simulations exploring the effects of excited-state energy splitting, symmetric and asymmetric fluctuations, and excited-state lifetime show that the time scales of the peak shift decay in the three-level system largely reflect the same dynamics as in the two-level system. However, the asymptotic peak shift, which is a clear indicator of inhomogeneous broadening in a two-level system, must be interpreted more carefully for three-level systems, as it is also influenced by the magnitude of the excited-state splitting. The calculated signals qualitatively reproduce the data.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1063/1.2186318 | DOI Listing |
Pharmaceutics
January 2025
Department of Pharmaceutics, Faculty of Pharmacy, Nahda University, Beni Suef 62764, Egypt.
Liver cancer is a prevalent form of carcinoma worldwide. A novel chitosan-coated optimized formulation capped with irradiated silver nanoparticles (INops) was fabricated to boost the anti-malignant impact of rosuvastatin calcium (RC). Using a 2-factorial design, eight formulations were produced using the solvent evaporation process.
View Article and Find Full Text PDFPharmaceuticals (Basel)
January 2025
Department of Vascular Surgery, Medical School, University of Pécs, H-7624 Pécs, Hungary.
: Peripheral artery disease (PAD) is a prevalent vascular condition characterized by arterial narrowing, which impairs blood flow and manifests as intermittent claudication, a pain or cramping sensation induced by physical activity or ambulation. Walking distance is a crucial clinical indicator of peripheral artery disease, and it correlates with the disease severity and risk of mortality. It reflects the severity of the disease, with reduced mobility indicating an increased risk of morbidity.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Department of Applied Physics and Science Education, Eindhoven Hendrik Casimir Institute, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven, The Netherlands.
The design of optical sensors aims at providing, among other things, the highest precision in the determination of the target measurand. Many sensor systems rely on a spectral transducer to map changes in the measurand into spectral shifts of a resonance peak in the reflection or transmission spectrum, which is measured by a readout device (e.g.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Institute of Telecommunications, AGH University of Krakow, al. Mickiewicza 30, 30-059 Krakow, Poland.
In this paper, the idea of a radar based on orthogonal frequency division multiplexing (OFDM) is applied to 5G NR Positioning Reference Signals (PRS). This study demonstrates how the estimation of the communication channel using the PRS can be applied for the identification of objects moving near the 5G NR receiver. In this context, this refers to a 5G NR base station capable of detecting a high-speed train (HST).
View Article and Find Full Text PDFSensors (Basel)
January 2025
Soreq NRC, Yavne 81800, Israel.
Fiber Bragg gratings (FBGs) inscribed by UV light and different femtosecond laser techniques (phase mask, point-by-point, and plane-by-plane) were exposed-in several irradiation cycles-to accumulated high doses of gamma rays (up to 124 MGy) and neutron fluence (8.7 × 10/cm) in a research-grade nuclear reactor. The FBG peak wavelengths were measured continuously in order to monitor radiation-induced shifts.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!