Absolute linearity measurements on a PbS detector in the infrared.

Appl Opt

Optical Radiation Team, Division of Quality of Life, National Physical Laboratory, Teddington, UK.

Published: April 2006

The nonlinearity characteristics of a commercially available thin-film photoconductive PbS detector were experimentally investigated in the infrared using the National Physical Laboratory detector linearity characterization facility. The deviation from linearity of this detector was shown to be significant even for relatively low values of radiant power incident on the active area of the detector. For example, the linearity factor was approximately 0.8 when 0.6 microW of radiant power at a wavelength of 2.2 microm was illuminating a spot of 1 mm in diameter on the active area of the PbS detector. These figures demonstrate the poor linearity characteristics of this detector and provide a warning to other users of PbS detection systems. The deviation from linearity was shown to be a function of the size of the spot being illuminated on the detector active area, as well as the wavelength of the incident radiation. The deviation from linearity was shown to be a function of irradiance illuminating the detector for irradiance values lower than 1 microW mm(-2).

Download full-text PDF

Source
http://dx.doi.org/10.1364/ao.45.002381DOI Listing

Publication Analysis

Top Keywords

pbs detector
12
deviation linearity
12
active area
12
detector
9
radiant power
8
linearity function
8
linearity
6
absolute linearity
4
linearity measurements
4
pbs
4

Similar Publications

Background: This manuscript describes modifications to a pencil beam scanning (PBS) proton gantry that enables ultra-high dose rates (UHDR) irradiation, including treatment planning and validation.

Methods: Beamline modifications consisted of opening the energy slits and setting the degrader to pass-through mode to maximize the dose rate. A range shifter was inserted upstream from the isocenter to enlarge the spot size and make it rotationally symmetric.

View Article and Find Full Text PDF

An empirical study of object detection models for the detection of iron deficiency anemia using peripheral blood smear images.

Biomed Phys Eng Express

December 2024

Department of Pathology, Kasturba Medical College, Manipal, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India.

Iron Deficiency Anemia (IDA) is the nutritional disorder that occurs when the body does not contain enough iron, an essential component of hemoglobin (Hb). The World Health Organization (WHO) estimated that IDA is the main cause of anemia in 1.62 billion cases worldwide [1].

View Article and Find Full Text PDF

Background: Pre-clinical studies demonstrate that delivering a high dose at a high dose rate result in less toxicity while maintaining tumor control, known as the FLASH effect. In proton therapy, clinical trials have started using 250 MeV transmission beams and more trials are foreseen. A novel aspect of FLASH treatments, compared to conventional radiotherapy, is the importance of dose rate next to dose and geometry.

View Article and Find Full Text PDF

Molecularly imprinted fluorescence sensor chip for lactate measurement.

Microsyst Nanoeng

November 2024

Chemical and Biological Engineering, University of British Columbia, Vancouver, Canada.

Lactate measurements provide an opportunity to conveniently evaluate bodily functions and sports performance. A molecularly imprinted fluorescence biochip provides an innovative way to achieve lactate measurement and overcomes the limitations of enzyme-based sensors. To realize this goal, ZnO quantum dots (QDs), a biocompatible sensing material, were combined with selective receptors comprised of molecularly imprinted polymers (MIPs).

View Article and Find Full Text PDF

Halogenated monopyridinium oximes are less effective in reactivation of phosphylated cholinesterases than bisquaternary oximes.

Bioorg Chem

December 2024

University of Hradec Kralove, Faculty of Science, Department of Chemistry, Rokitanskeho 62, 500 03 Hradec Kralove, Czech Republic; University Hospital in Hradec Kralove, Biomedical Research Centre, Sokolska 581, 500 05 Hradec Kralove, Czech Republic. Electronic address:

Mono-quaternary pyridinium oximes derived from K-oximes K027, K048 and K203 were designed, synthesized and evaluated for the reactivation of organophosphate-inhibited cholinesterases. The incorporation of the halogen atoms to the structure decreased the pK value of the oxime group resulting in an increased formation of oximate necessary for reactivation. The stability and pK values were found to be similar to analogous bis-quaternary compounds.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!