Objective: To evaluate the value of X-ray and spiral computed tomography (SCT) in the diagnosis of Swyer-James syndrome (SJS).

Methods: A total of 28 patients, 12 males and 16 females, were studied retrospectively. Ages ranged from 11 to 57 years, the mean age was 32 years. All patients underwent inspiratory chest X-ray films, 5 with expiratory chest films and 1 with bronchogram. Furthermore, inspiratory and expiratory SCT scans were performed. The SCT findings were analyzed and compared with X-ray films.

Results: SCT demonstrated 56 lobes with hyperlucency and diminished vascularity. The size of 51 lobes were smaller and 5 were normal. X-ray films showed that hyperlucency was only in 29 lobes, in which 19 lobes were small-sized and the other 10 lobes normal. There were 56 lobes with air-trapping on expiratory SCT scans, but only 5 lobes with air-trapping on expiratory X-ray films. Bronchogram in 1 case demonstrated bronchiectasis and bronchiolitis obliterans. SCT showed 24 patients with bronchiectasis, 9 patients with tuberculosis, 10 patients with bronchiolitis, and 2 with segmental collapse.

Conclusion: SCT scan is superior to chest radiography in the diagnosis and differential diagnosis of SJS.

Download full-text PDF

Source

Publication Analysis

Top Keywords

x-ray films
12
spiral computed
8
computed tomography
8
swyer-james syndrome
8
films bronchogram
8
expiratory sct
8
sct scans
8
lobes air-trapping
8
air-trapping expiratory
8
sct
7

Similar Publications

Background The thyroid gland is the most susceptible organ to radiation during the exposure of teeth because the thyroid area appears to be within the primary beam, and the dose levels are relatively high even after using collimation. This study aims to develop an eco-friendly thyroid shield by reusing lead foils from intra-oral periapical radiographic films and evaluate its effectiveness in intraoral radiography. Methods A total of 16 patients undergoing endodontic procedures who gave written consent to participate in the study were included and divided into four categories: anterior, canine, premolar, and molar.

View Article and Find Full Text PDF

Gelatin is a versatile substance extensively used in medical and pharmaceutical industries for many applications, including capsule shells, X-ray film, infusion for plasma substitute, and the fabricating of artificial tissue. Fish scale gelatin is a profitable alternative source as a halal material despite its inferior quality. An addition of phenolic cross-linker may enhance the qualities of fish scale gelatin.

View Article and Find Full Text PDF

Cuprous oxide (CuO) thin films were chemically deposited from a solution onto GaAs(100) and (111) substrates using a simple three-component solution at near-ambient temperatures (10-60 °C). Interestingly, a similar deposition onto various other substrates including Si(100), Si(111), glass, fluorine-doped tin oxide, InP, and quartz resulted in no film formation. Films deposited on both GaAs(100) and (111) were found alongside substantial etching of the substrates.

View Article and Find Full Text PDF

Surface-anchored metal-organic frameworks (surMOFs) are crystalline, nanoporous, supramolecular materials mounted to substrates that have the potential for integration within device architectures relevant for a variety of electronic, photonic, sensing, and gas storage applications. This research investigates the thin film formation of the Cu-BDC (copper benzene-1,4-dicarboxylate) MOF system on a carboxylic acid-terminated self-assembled monolayer by alternating deposition of solution-phase inorganic and organic precursors. X-ray diffraction (XRD) and atomic force microscopy (AFM) characterization demonstrate that crystalline Cu-BDC thin films are formed via Volmer-Weber growth.

View Article and Find Full Text PDF

Purpose: Due to the extensive use of radiation in various fields, such as food safety, sterilizing surgical materials, and medical diagnostics, it is essential to minimize radiation exposure for both patients and healthcare professionals, even at low doses. To meet this requirement, a composite film has been developed using polyvinyl alcohol (PVA) polymer and nitro blue tetrazolium (NBT) dye to measure low radiation doses effectively.

Methods: Various concentrations of NBT dye (ranging from 0.

View Article and Find Full Text PDF