The design and optimization of light-based analytical devices often require optical characterization of materials involved in their construction. With the aim of benefiting lab-on-a-chip applications, a transmission spectrometric method for determining refractive indices, n, of transparent solids is presented here. Angular dependence of the reflection coefficient between material-air interfaces constitutes the basis of the procedure. Firstly, the method is studied via simulation, using a theoretical algorithm that describes the light propagation through the sample slide, to assess the potentially attainable accuracy. Simulations also serve to specify the angles at which measurements should be taken. Secondly, a visible light source and an optical fiber spectrometer are used to perform measurements on three commonly used materials in optical lab-on-a-chip devices. A nonlinear regression subroutine fits experimental data to the proposed theoretical model and is used to obtain n. Because the attainable precision using this method of refractive index determination is dictated by the uncertainty in the transmission measurements, the precision (with 95% confidence) for mechanically rigid samples, namely glass and poly(methyl methacrylate) (PMMA), is higher than those estimated for the elastomer sample (in-house-molded poly(dimethylsiloxane) (PDMS)). At wavelengths with the highest signal-to-noise ratio for the spectrometer setup, the estimated refractive indices were 1.43+/-0.05 (580 nm) for PDMS, 1.54+/-0.02 (546 nm) for glass, and 1.485+/-0.005 (656 nm) for PMMA. Accurate refractive index estimations with an average precision equal to 0.01 refractive index units (RIU) were obtained for PMMA and glass samples, and an average precision of 0.09 RIU for the PDMS molded slide between 550 and 750 nm was obtained.

Download full-text PDF

Source
http://dx.doi.org/10.1366/000370206776342526DOI Listing

Publication Analysis

Top Keywords

lab-on-a-chip applications
8
refractive indices
8
average precision
8
refractive
6
spectrometric determination
4
determination refractive
4
optical
4
refractive optical
4
optical wave
4
wave guiding
4

Similar Publications

Despite being a high-resolution separation technique, deterministic lateral displacement (DLD) technology is facing multiple challenges with regard to design, manufacture, and operation of pertinent devices. This work specifically aims at alleviating difficulties associated with design and manufacture of DLD chips. The process of design and production of computer-aided design (CAD) mask layout files that are typically required for computational modeling analysis, optimization, as well as for manufacturing DLD-based micro/nanofluidic chips is complex, time-consuming, and often necessitates a high level of expertise in the field.

View Article and Find Full Text PDF

Quantitative investigation of a 3D bubble trapper in a high shear stress microfluidic chip using computational fluid dynamics and L*A*B* color space.

Biomed Microdevices

January 2025

Chakri Naruebodindra Medical Institute, Faculty of Medicine Ramathibodi Hospital, Mahidol University, 111 Suwannabhumi Canal Rd, Bang Pla, Bang Phli District, Samut Prakan, 10540, Thailand.

Microfluidic chips often face challenges related to the formation and accumulation of air bubbles, which can hinder their performance. This study investigated a bubble trapping mechanism integrated into microfluidic chip to address this issue. Microfluidic chip design includes a high shear stress section of fluid flow that can generate up to 2.

View Article and Find Full Text PDF

Digital recombinase polymerase amplification chip based on asymmetric contact angle composite interface.

Anal Chim Acta

February 2025

Institute of Microfluidic Chip Development in Biomedical Engineering, College of Information Science and Technology, Beijing University of Chemical Technology, Beijing, 100029, China. Electronic address:

Background: Digital recombinase polymerase amplification (dRPA) is an effective tool for the absolute quantification of nucleic acids and the detection of rare mutations. Due to the high viscosity or other physical properties of the reagent, this can compromise the accuracy and reproducibility of detection results, which limits the broader adoption and practical application of this technology. In this study, we developed an asymmetric contact angle digital isothermal detection (ACA-DID) chip and optimized the ACA-DID chip structure to achieve rapid digital recombinase polymerase amplification.

View Article and Find Full Text PDF

Measuring virus in biofluids is complicated by confounding biomolecules coisolated with viral nucleic acids. To address this, we developed an affinity-based microfluidic device for specific capture of intact severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Our approach used an engineered angiotensin-converting enzyme 2 to capture intact virus from plasma and other complex biofluids.

View Article and Find Full Text PDF

Background: Adrenaline and glucose are essential biomarkers in human body for maintaining metabolic balance. Abnormal levels of adrenaline and glucose are associated with various diseases. Therefore, it is important to design portable, on-site devices for rapid adrenaline and glucose analysis to safeguard health.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!