A 2-D tissue-equivalent sheet-type dosemeter (NTL sheet) was developed using thermoluminescent material of LiF:Mg,Cu,P (NTL-250). The energy responses of the NTL sheet and NTL-250 powder were measured with 10-150 keV monoenergetic photons from synchrotron radiation at SPring-8. The sample was irradiated by a rotational method for the uniform irradiation with the narrow beam. Linearity of the NTL-250 was confirmed up to 2 Gy. Energy responses of the NTL sheet and NTL-250 powder were close to that of soft tissue. On the other hand, the BaSO(4) sheet, which has been used practically, showed the response that the sensitivity approximately 60 keV was 100 times higher than that for (60)Co gamma rays. Therefore the NTL sheet can be said to have excellent properties for dose measurements.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/rpd/nci527 | DOI Listing |
Dev Biol
October 2007
Department of Neurobiology and Anatomy, University of Utah, Salt Lake City, UT 84112, USA.
The brain, heart and gastro-intestinal tract develop distinct left-right (LR) asymmetries. Asymmetric cilia-dependent fluid flow in the embryonic node in mouse, Kupffer's vesicle in zebrafish, notochordal plate in rabbit and gastrocoel roof plate in frog appears to be a conserved mechanism that directs LR asymmetric gene expression and establishes the orientation of organ asymmetry. However, the cellular processes and genetic pathways that control the formation of these essential ciliated structures are unknown.
View Article and Find Full Text PDFRadiat Prot Dosimetry
December 2006
National Maritime Research Institute, Mitaka, Tokyo 181-0004, Japan.
A (6)LiF-rich thermoluminescent sheet-type dosemeter ((6)LiF-rich NTL sheet) was developed for neutron 2D dosimetry. The dosemeter utilises the (6)Li(n, alpha)(3)H reaction to detect thermal neutrons. Responses of the (6)LiF-rich NTL sheet to neutrons were measured at the neutron beam irradiation facility for BNCT in JRR-4 Research Reactor at the Japan Atomic Energy Research Institute.
View Article and Find Full Text PDFRadiat Prot Dosimetry
December 2006
National Maritime Research Institute, Mitaka, Tokyo 181-0004, Japan.
A 2-D tissue-equivalent sheet-type dosemeter (NTL sheet) was developed using thermoluminescent material of LiF:Mg,Cu,P (NTL-250). The energy responses of the NTL sheet and NTL-250 powder were measured with 10-150 keV monoenergetic photons from synchrotron radiation at SPring-8. The sample was irradiated by a rotational method for the uniform irradiation with the narrow beam.