A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Tranexamic acid reduces postoperative bleeding in off-pump coronary artery bypass grafting. | LitMetric

AI Article Synopsis

  • Tranexamic acid (TA) was tested for its effects on blood loss during off-pump coronary artery bypass surgery, with 76 patients split between receiving TA or saline.
  • Blood loss was significantly lower in the TA group compared to the control group at both 6 and 24 hours post-surgery.
  • While D-dimer levels increased after surgery, those in the TA group were notably lower than in the control group, and overall early clinical outcomes were similar between both groups.

Article Abstract

Objective: Tranexamic acid (TA) reduces blood loss in coronary artery surgery with cardiopulmonary bypass. The present prospective study was designed to investigate its hemostatic effect in off-pump coronary artery bypass (OPCAB).

Method: Seventy-six patients undergoing elective OPCAB were randomized into two groups, received TA (0.75 g loading dose before surgery and 250 mg/h during surgery, gross dose: 1.5 g, n=36) and saline solution (control, n=40), respectively. Perioperative blood samples were collected. Hematochemical parameters including platelet adhesion rate, D-dimer and fibrinopeptide-A (FPA) were analysis. Volume of blood loss, blood transfusion and other clinical data were recorded throughout the perioperative period.

Results: Cumulative blood loss was significantly reduced in the TA group as compared to the controls postoperatively (6 hrs (median [25th-75th]): TA: 200.0 [140.0-230.0] ml,

Control: 225.0 [200.0-347.5.0] ml, p=0.009; 24 hrs: TA: 440.0 [270.0-605.0] ml,

Control: 655.0 [500.0-920.0] ml, p<0.001). Number of patients received blood transfusion in each group was similar. Levels of D-dimer rose significantly after surgery, and were significantly lower in the TA group than that in controls. Platelet adhesion rate and FPA levels remained at baseline levels after the operation in two groups. Early clinical outcomes were similar between groups.

Conclusion: The results indicated that tranexamic acid limits fibrinolysis and reduces blood loss after off-pump coronary artery bypass surgery.

Download full-text PDF

Source
http://dx.doi.org/10.1080/14017430500519864DOI Listing

Publication Analysis

Top Keywords

coronary artery
12
blood loss
12
tranexamic acid
8
acid reduces
8
off-pump coronary
8
artery bypass
8
blood
5
reduces postoperative
4
postoperative bleeding
4
bleeding off-pump
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!