Efficient deconvolution of noisy periodic interference signals.

J Opt Soc Am A Opt Image Sci Vis

Department of Physics, University of Northern Iowa, Cedar Falls 50614, USA.

Published: April 2006

The interference signal formed by combining two coherent light beams carries information on the path difference between the beams. When the path difference is a periodic function of time, as, for example, when one beam is reflected from a vibrating surface and the other from a fixed surface, the interference signal is periodic with the same period as the vibrating surface. Bessel functions provide an elegant and efficient means for deconvoluting such periodic interference signals, thus making it possible to obtain the displacement of the moving surface with nanometer resolution. Here we describe the mathematical basis for the signal deconvolution and employ this technique to obtain the amplitude of miniature capillary waves on water as a test case.

Download full-text PDF

Source
http://dx.doi.org/10.1364/josaa.23.000902DOI Listing

Publication Analysis

Top Keywords

periodic interference
8
interference signals
8
interference signal
8
path difference
8
vibrating surface
8
efficient deconvolution
4
deconvolution noisy
4
periodic
4
noisy periodic
4
interference
4

Similar Publications

Importance: Multisystem inflammatory syndrome in children (MIS-C) is a life-threatening complication of COVID-19 infection. Data on midterm outcomes are limited.

Objective: To characterize the frequency and time course of cardiac dysfunction (left ventricular ejection fraction [LVEF] <55%), coronary artery aneurysms (z score ≥2.

View Article and Find Full Text PDF

Post-synthesis surface modification of Cu/Zr metal azolate framework: A pathway to highly sensitive electrochemical biosensors for atrazine detection.

Anal Chim Acta

February 2025

Dept. of Electronic Materials Engineering, Kwangwoon University, Seoul, 01897, Republic of Korea. Electronic address:

Background: Atrazine (ATZ), a pesticide that poses serious health problems, is observed in the environment, thereby prompting its periodic monitoring and control using functional biosensors. However, established methods for ATZ detection have limited applicability. Two-dimensional (2D) metal azolate frameworks (MAF) have a higher surface area per unit volume and provide easier access to active sites.

View Article and Find Full Text PDF

Presurgical anxiety and acute postsurgical pain predict worse chronic pain profiles after total knee/hip arthroplasty.

Arch Orthop Trauma Surg

January 2025

Life and Health Sciences Research Institute (ICVS), School of Medicine, University of Minho, Campus de Gualtar, Braga, 4710-057, Portugal.

Introduction: Total joint arthroplasties generally achieve good outcomes, but chronic pain and disability are a significant burden after these interventions. Acknowledging relevant risk factors can inform preventive strategies. This study aimed to identify chronic pain profiles 6 months after arthroplasty using the ICD-11 (International Classification of Diseases) classification and to find pre and postsurgical predictors of these profiles.

View Article and Find Full Text PDF

A 36-year-old woman diagnosed with complicated cholecystolithiasis underwent elective laparoscopic cholecystectomy (LC), then converted to open cholecystectomy because of a massive intraoperative bleeding. Hemostasis was performed with clipping and suturing the source of bleeding. In post-operative period, the patient suffered from persistent anemia associated with hemoperitoneum diagnosed through abdominal CT scanning, in absence of any sign of active bleeding.

View Article and Find Full Text PDF

A parallelized field-programmable gate array (FPGA) architecture is proposed to realize an ultra-fast, compact, and low-cost dual-channel ultra-wideband (UWB) pulsed-radar system. This approach resolves the main shortcoming of current FPGA-based radars, namely their low processing throughput, which leads to a significant loss of data provided by the radar receiver. The architecture is integrated with an in-house UWB pulsed radar operating at a sampling rate of 20 gigasamples per second (GSa/s).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!