A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Objective evaluation of changes in left ventricular and atrial volumes during parabolic flight using real-time three-dimensional echocardiography. | LitMetric

Objective evaluation of changes in left ventricular and atrial volumes during parabolic flight using real-time three-dimensional echocardiography.

J Appl Physiol (1985)

Politecnico di Milano, Dipartimento di Bioingegneria, Piazza L. da Vinci, 32, 20133 Milano, Italy.

Published: August 2006

We tested the feasibility of real-time three-dimensional (3D) echocardiographic (RT3DE) imaging to measure left heart volumes at different gravity during parabolic flight and studied the effects of lower body negative pressure (LBNP) as a countermeasure. Weightlessness-related changes in cardiac function have been previously studied during spaceflights using both 2D and 3D echocardiography. Several technical factors, such as inability to provide real-time analysis and the need for laborious endocardial definition, have limited its usefulness. RT3DE imaging overcomes these limitations by acquiring real-time pyramidal data sets encompassing the entire ventricle. RT3DE data sets were obtained (Philips 7500, X3) during breath hold in 16 unmedicated normal subjects in upright standing position at different gravity phases during parabolic flight (normogravity, 1 Gz; hypergravity, 1.8 Gz; microgravity, 0 Gz), with LBNP applied (-50 mmHg) at 0 Gz in selected parabolas. RT3DE imaging during parabolic flight was feasible in 14 of 16 subjects. Data were analyzed (Tomtec) to quantify left ventricular (LV) and atrial (LA) volumes at end diastole and end systole, which significantly decreased at 1.8 Gz and increased at 0 Gz. While ejection fraction did not change with gravity, stroke volume was reduced by 16% at 1.8 Gz and increased by 20% at 0 Gz, but it was not significantly different from 1 Gz values with LBNP. RT3DE during parabolic flight is feasible and provides the basis for accurate quantification of LV and LA volume changes with gravity. As LBNP counteracted the increase of LV and LA volumes caused by changes in venous return, it may be effectively used for preventing cardiac dilatation during 0 Gz.

Download full-text PDF

Source
http://dx.doi.org/10.1152/japplphysiol.00014.2006DOI Listing

Publication Analysis

Top Keywords

parabolic flight
20
rt3de imaging
12
left ventricular
8
ventricular atrial
8
atrial volumes
8
real-time three-dimensional
8
data sets
8
flight feasible
8
parabolic
5
flight
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!