Relevant bradycardias during percutaneous coronary intervention (PCI) are a rare event, but they require immediate therapy by temporary pacing. However, transvenous pacing is associated with frequent and severe complications. Therefore, we wanted to evaluate the safety and reliability of trans-coronary pacing by means of a PCI guidewire. Coronary pacing was applied to 70 consecutive patients undergoing PCI. Pacing was performed before and after PCI in a unipolar setting using standard guidewires as a cathode and a skin electrode as an anode. Both were connected to an external pacemaker. Coronary pacing (maximum output at 10 V, impulse duration 2.5 ms) was effective in 60 of 70 patients (85.7%). Successful pacing was achieved in the LAD and diagonal branches in 90% (27 of 30 Pts.), in the LCX and marginal branches 84.2% (16 of 19 Pts.) and in the RCA in 81% (17 of 21 Pts.). Pacing thresholds were comparable in all vessels within a range of 1-10 V averaging 6.6 +/- 2.3 V before and 6.6 +/- 2.2 V after PCI. The impedance ranged from 190-544 Omega with mean pacing impedance for coronary pacing of 424 Omega before and 416 Omega after PCI, respectively. Significant bradycardias during PCI occurred in 7 cases (10%). In three cases (4.3%) temporary coronary pacing became necessary at a maximum pacing duration of 3 min. There were no severe side effects. Coronary spasm occurred in 3 cases (4.3%) after pacing and was promptly reversible after intracoronary application of nitroglycerine. It is concluded that coronary pacing is a safe and feasible method for the treatment of bradycardias during PCI. It avoids additional venous puncture under hemodynamically unstable conditions and subsequent transvenous pacing, which is accompanied by potentially severe complications and additional costs.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00392-006-0361-3 | DOI Listing |
Pacing Clin Electrophysiol
January 2025
Department of Cardiology, The Second Affiliated Hospital of Soochow University, Suzhou, Jiangsu, China.
Background: Conduction system pacing (CSP) has been reported to improve clinical outcomes in comparison of right ventricular pacing (RVP). However, the performance between CSP and RVP on the risk of new-onset atrial fibrillation (AF) remains elusive.
Methods: Four online databases were systematically searched up to July 1, 2024.
Eur Heart J Case Rep
January 2025
1st Department of Arrhythmia, National Institute of Cardiology, 42 Alpejska Street, 04-628 Warsaw, Poland.
Background: Transvenous lead extraction (TLE) has become an essential component of lead management strategies, but it carries the risk of severe complications, including damage to the tricuspid valve. Currently, there are no established predictors that can help prevent these complications.
Case Summary: An 84-year-old male with a dual-chamber pacemaker was admitted to the hospital due to a pocket fistula resulting from a local infection.
Eur Heart J Case Rep
January 2025
Department of Cardiology, Hyogo Prefectural Awaji Medical Center, Sumoto, Japan.
Background: Atrial infarction is a complication of myocardial infarction with ventricular infarction; however, isolated atrial infarction (IAI) has rarely been reported. Herein, we report a case of IAI associated with sick sinus syndrome and atrial fibrillation (AF).
Case Summary: An 83-year-old woman was brought to the emergency department with a complaint of general malaise.
Biomaterials
January 2025
Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, 78712, USA. Electronic address:
Direct pacing of the mid myocardium where re-entry originates can be used to prevent ventricular arrhythmias and circumvent the need for painful defibrillation or cardiac ablation. However, there are no pacing electrodes small enough to navigate the coronary veins that cross these culprit scar regions. To address this need, we have developed an injectable ionically conductive hydrogel electrode that can fill the epicardial coronary veins and transform them into flexible electrodes.
View Article and Find Full Text PDFCardiol Rev
January 2025
Department of Cardiology, Detroit Medical Center, Detroit, MI.
Congenital heart disease (CHD) is the most common congenital anomaly in newborns. Advances in catheter and surgical techniques led to the majority of these patients surviving into adulthood, leading to evolving challenges due to the emergence of long-term complications such as arrhythmias. Interventional electrophysiology (EP) has had remarkable advances over the last few decades, and various techniques and devices have been explored to treat adult patients with CHD.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!