In this study, a newly-synthesized metalloporphyrin, Gd-chlorin (PB Chlorin), was investigated by using a simple tissue phantom to test its efficacy as an MRI contrast agent. This study demonstrated the potential activity of Gd-chlorin as not only a MRI contrast agent, but also as a PDT photosensitizer by using a simple tissue phantom and conducting a very brief MRI experiment.

Download full-text PDF

Source
http://dx.doi.org/10.1007/BF02969390DOI Listing

Publication Analysis

Top Keywords

mri contrast
12
contrast agent
12
agent study
8
simple tissue
8
tissue phantom
8
gadolinium-chlorin tumor
4
tumor specific
4
mri
4
specific mri
4
study newly-synthesized
4

Similar Publications

Background: Computed tomography (CT) is the gold standard imaging modality for the assessment of 3D bony morphology but incurs the cost of ionizing radiation exposure. High-resolution 3D magnetic resonance imaging (MRI) with CT-like bone contrast (CLBC) may provide an alternative to CT in allowing complete evaluation of both bony and soft tissue structures with a single MRI examination.

Purpose: To review the technical aspects of an optimized stack-of-stars 3D gradient recalled echo pulse sequence method (3D-Bone) in generating 3D MR images with CLBC, and to present a pictorial review of the utility of 3D-Bone in the clinical assessment of common musculoskeletal conditions.

View Article and Find Full Text PDF

Zero echo time (zero-TE) pulse sequences provide a quiet and artifact-free alternative to conventional functional magnetic resonance imaging (fMRI) pulse sequences. The fast readouts (<1 ms) utilized in zero-TE fMRI produce an image contrast with negligible contributions from blood oxygenation level-dependent (BOLD) mechanisms, yet the zero-TE contrast is highly sensitive to brain function. However, the precise relationship between the zero-TE contrast and neuronal activity has not been determined.

View Article and Find Full Text PDF

Background: Magnetic resonance imaging (MRI) measurement parameters-the standard noninvasive diagnostic method for rotator cuff tears (RCTs)-have been used to compare groups with and without RCTs. Arthroscopy is used in definitive diagnosis and treatment.

Purposes: To evaluate the association between RCT and shoulder angles and distances on MRI in patients with and without arthroscopically validated RCT and to determine whether the degree of rotator cuff fatty degeneration affects the MRI measurements.

View Article and Find Full Text PDF

Contrast-enhanced ultrasonography as a method of monitoring focal liver lesions - initial report.

Clin Exp Hepatol

March 2024

Department of Radiology and Diagnostic Imaging, Norbert Barlicki Memorial Teaching Hospital No. 1, Medical University of Lodz, Poland.

Aim Of The Study: Hepatocellular adenoma (HCA) and focal nodular hyperplasia (FNH) are benign liver tumors. Hepatocellular adenoma has potential for growth, metaplasia and rupture; therefore, it should be monitored long term. In the current guidelines biopsy is not recommended in the standard diagnostic protocol.

View Article and Find Full Text PDF

Introduction: The following presentation explores the diagnostic potential of Contrast-Enhanced Mammography (CEM) in evaluating and managing Paget's Disease (PD) of the breast, particularly as an alternative or complementary tool to Magnetic Resonance Imaging (MRI) in cases where MRI is contraindicated or inconclusive.

Clinical Cases: Two clinical cases of PD diagnosed at our Breast Imaging Division between January and May 2024 were analyzed using CEM. These cases involved imaging techniques, including Digital Mammography (DM), Breast Ultrasound (US), MRI and CEM, alongside histopathological confirmation through nipple-areolar complex (NAC) punch biopsies.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!