Voxel-based mouse and rat models for internal dose calculations.

J Nucl Med

Department of Radiology and Radiological Sciences, Vanderbilt University, 1161 21st Ave. S, Nashville, Tennessee 37232-2675, USA.

Published: April 2006

Unlabelled: The ability to estimate absorbed doses in experimental animals to which radiolabeled material has been administered may be important in explaining and controlling potential radiation toxicity observed during preclinical trials. Most previously reported models for establishing doses to small animals have been stylized and mathematically based. This study establishes dose factors for internal sources in realistic models of a typical mouse and a typical rat, based on image data obtained using a dedicated small-animal CT scanner.

Methods: A transgenic mouse (body mass, 27 g) and a Sprague-Dawley rat (body mass, 248 g) were imaged using the dedicated small-animal CT scanner. Identified organs were segmented using computer tools that Vanderbilt University applies to process human images for 3-dimensional dosimetry. Monte Carlo N-particle transport code (MCNP) input files were prepared from the 3-dimensional, voxel-based image data. Using methods established for human studies, radiation transport calculations of absorbed fractions (AFs) were performed using MCNP, version 4C, on the segmented images, and dose conversion factors for several radionuclides were developed.

Results: AFs were established at discrete energies for electron and photon sources assumed to be uniformly distributed throughout approximately 10 source and target regions in both models. Electron self-irradiation AFs were significantly less than 1.0 for many organs, at energies above 0.5 MeV, and significant cross irradiation was observed for high-energy electrons, such as those from (90)Y or (188)Re, in many organs. Calculated dose conversion factors reflected these trends and agreed well with the results of other authors who have undertaken similar investigations.

Conclusion: The AFs calculated in this study will be useful in determining the dose to organs for mice and rats similar in size to those studied here. The segmented, voxel-based models developed here can be used for external dose calculations as well.

Download full-text PDF

Source

Publication Analysis

Top Keywords

dose calculations
8
image data
8
dedicated small-animal
8
body mass
8
dose conversion
8
conversion factors
8
dose
6
models
5
voxel-based mouse
4
mouse rat
4

Similar Publications

The revised EFSA 2023 Guidance on the risk assessment of plant protection products for birds and mammals emphasises vulnerability as a relevant criterion for focal species (FS) selection rather than prevalence. The EFSA 2023 Guidance suggests to rank FS candidates for each dietary group according to their expected exposure by estimating a species-specific daily dietary dose (DDD). Species experiencing higher exposure would be ranked as potentially more vulnerable and can be identified as FS candidates.

View Article and Find Full Text PDF

Background: Individuals with spinal cord injury (SCI) commonly have autonomic dysreflexia (AD) with increased sympathetic activity. After SCI, individuals have decreased baroreflex sensitivity and increased vascular responsiveness.

Objective: To evaluate the relationship between baroreflex and blood vessel sensitivity with AD symptoms.

View Article and Find Full Text PDF

Effectiveness and Safety of Dose-Specific DOACs in Patients With Atrial Fibrillation: A Systematic Review and Network Meta-Analysis.

Cardiovasc Ther

January 2025

College of Pharmacy and Institute of Pharmaceutical Science and Technology, Hanyang University, Ansan-si, Gyeonggi-do, Republic of Korea.

Dose adjustments of direct-acting oral anticoagulants (DOACs) for atrial fibrillation are based on pivotal clinical trials assessing their effectiveness and safety in controlled settings. However, the appropriateness of these dosing strategies in real-world practice is uncertain. The purpose of this study is to compare the effectiveness and safety of dose-specific DOACs with those of warfarin.

View Article and Find Full Text PDF

Epidemiology of antibiotic consumption and resistance in Mauritius.

Front Antibiot

April 2024

Surveillance Epidemiologique et Gestion des Alertes (SEGA) One Health network, Indian Ocean Commission, Ebene, Mauritius.

Introduction: This study aims at determining the pattern of antibiotic consumption and resistance in Mauritius, a tropical island in the Indian Ocean.

Methodology: Antibiotic consumption was measured in kilograms of purchased antibiotics and also in defined daily dose (DDD) in different health institutions from 2015 to 2017. Data on antibiotic resistance was collected at the Central Health Laboratory (CHL) at Victoria Hospital and at Jeetoo Hospital Laboratory, where antibiotic sensitivity testing is done for all public health institutions.

View Article and Find Full Text PDF

The impact of serum sodium variability on surgical patients with aneurysmal subarachnoid hemorrhage.

Neurosurg Rev

January 2025

Department of Neurosurgery, West China Hospital, Sichuan University, No. 37, Guo Xue Xiang, Chengdu, Sichuan, 610041, China.

Currently, limited evidence exists on the impact of serum sodium variability in patients with aneurysmal subarachnoid hemorrhage (SAH) who underwent surgical clipping. We aimed to perform a detailed examination of the relationship between sodium variability and mortality in these patients. We conducted a cohort study including adult patients with aneurysmal SAH who underwent surgical clipping at a university hospital.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!