Risks of third-trimester amniocentesis are considered minimal; however, only case series have been reported. We performed a case-control study in which women undergoing third-trimester amniocentesis were matched with controls undergoing antenatal testing for similar indications to determine adverse outcomes associated with the procedure. Cases undergoing amniocentesis at > 32 weeks for fetal lung maturity assessment followed by antepartum testing with nonstress test and amniotic fluid index determination were matched with controls undergoing only antepartum testing based on gestational age at testing and maternal age. The main outcome variable was a composite occurrence of obstetric complications within 48 hours of testing, including urgent delivery, placental abruption, premature rupture of membranes (PROM), perinatal death, or Apgar score at 5 minutes < 7. Statistical analysis included Fisher's exact test and Student T-test, with P < 0.05 considered significant. A total of 167 matched pairs of patients fulfilled the study criteria. Indications for both amniocentesis and antepartum testing, which included diabetes, preterm labor, and cholestasis, were similar in the two groups. As expected, gestational age at sampling/testing (36.4 +/- 1.4 [mean +/- standard deviation] versus 36.6 +/- 1.7 weeks; P = 0.2) and maternal age (31.4 +/- 5.8 versus 31.5 +/- 6.3 years; P = 0.9) were not different between cases and controls. The rate of the main outcome variable within 48 hours of testing was 0 of 167 among cases and 1 of 167 among controls. Amniocentesis in the third trimester is not associated with increased risk of urgent delivery, placental abruption, PROM, Apgar score at 5 minutes < 7, or perinatal death within 48 hours of the procedure.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1055/s-2006-934100 | DOI Listing |
Diagnostics (Basel)
December 2024
Department of Obstetrics and Gynecology, CHA Gangnam Medical Center, CHA University School of Medicine, Seoul 06125, Republic of Korea.
Background: To investigate prenatal ultrasound findings and the chromosomal outcomes of mosaic embryo transfer.
Methods: This retrospective study was conducted on pregnant women who underwent mosaic embryo transfer following blastocyst-stage preimplantation genetic testing for aneuploidy (PGT-A) at CHA Gangnam Medical Center from January 2021 to July 2024. Trophectoderm biopsy specimens were collected using standard protocols, and next-generation sequencing profiles were defined as mosaics when displaying copy number counts in the 20-80% range.
Prenat Diagn
December 2024
Obstetric Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy.
Objective: To determine outcomes at birth and postnatal sequelae of congenital cytomegalovirus (cCMV) infection following maternal primary infection in the first trimester with normal fetal brain imaging at midgestation.
Methods: A retrospective, single-center cohort study was conducted, including all cases of proven cCMV infection following maternal primary infection in the first trimester from 2014 until 2021 and normal fetal brain imaging before 22 weeks of gestation. All pregnancies were followed according to our protocol, which offers amniocentesis at least 8 weeks after the onset of infection, serial ultrasound scans, and a fetal MRI in the third trimester.
Viruses
August 2024
Fourth Department of Internal Medicine, University General Hospital Attikon, National and Kapodistrian University of Athens, 12462 Athens, Greece.
Primary cytomegalovirus infection during pregnancy has a high risk of vertical transmission, with severe fetal sequelae mainly associated with first-trimester infections. We conducted a retrospective analysis of 200 IU/kg cytomegalovirus-specific hyperimmune globulin (HIG), used in first-trimester maternal primary infections for congenital infection prevention. The primary outcome was vertical transmission, defined as neonatal viruria or positive amniocentesis if pregnancy was discontinued.
View Article and Find Full Text PDFPrenat Diagn
August 2024
Division of Medical Genetics, Stanford University Department of Pediatrics, Stanford, California, USA.
Due to abnormal prenatal ultrasound findings of femoral shortening and flattened facial profile, a G2P0 pregnant patient underwent an amniocentesis at 15 weeks of gestation for proband-only exome sequencing. Bioinformatic filtering for genes included on the laboratory's extended skeletal dysplasia panel identified a heterozygous, likely pathogenic, frameshift variant in DVL1 NM_001330311.2:c.
View Article and Find Full Text PDFAm J Obstet Gynecol
June 2024
Department of Molecular and Human Genetics, Baylor College of Medicine, Houston, TX; Division of Maternal-Fetal Medicine and Reproductive and Prenatal Genetics, Department of Obstetrics and Gynecology, Baylor College of Medicine and Texas Children's Fetal Center, Houston, TX. Electronic address:
Background: Amniocentesis for genetic diagnosis is most commonly done between 15 and 22 weeks of gestation but can be performed at later gestational ages. The safety and genetic diagnostic accuracy of amniocentesis have been well-established through numerous large-scale multicenter studies for procedures before 24 weeks, but comprehensive data on late amniocentesis remain sparse.
Objective: To evaluate the indications, diagnostic yield, safety, and maternal and fetal outcomes associated with amniocentesis performed at or beyond 24 weeks of gestation.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!