A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Low-pressure gas chromatography-ion trap mass spectrometry for the fast determination of polycyclic aromatic hydrocarbons in air samples. | LitMetric

Low-pressure gas chromatography-ion trap mass spectrometry for the fast determination of polycyclic aromatic hydrocarbons in air samples.

J Chromatogr A

Micro and Trace Analysis Center, Department of Chemistry, University of Antwerp, Universiteitsplein 1, B-2610 Antwerp, Belgium.

Published: May 2006

A low-pressure gas chromatography-ion trap mass spectrometry (LPGC-ITMS) method was investigated to shorten the analysis time for 18 US Environmental Protection Agency priority listed polycyclic aromatic hydrocarbons (PAHs). Their elution was optimised with a short, wide-bore column coupled to a deactivated capillary at the inlet end and with a long, conventional column to compare their analytical performance. The analytical figures of merit under optimal LPGC-ITMS conditions were determined with respect to chromatographic separation, S/N ratio, limit of detection and precision. The peak width at half height of 1.5s matched the ITMS duty cycle. Up to 16 PAHs in the molecular weight (MW) range of 128-278 Da could be separated in a very short time, i.e. less than 13 min using LPGC-ITMS, whereas with conventional GC-MS, it took approximately 40 min. However, LPGC-ITMS has a limited loss of separation power compared to that of conventional GC-MS due to the occurrence of three critical pairs for high-MW PAHs. For a practical evaluation, the LPGC-ITMS approach was applied to the determination of PAHs in gas and aerosol phase samples collected in the ambient air of Hasselt, Belgium.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2006.03.025DOI Listing

Publication Analysis

Top Keywords

low-pressure gas
8
gas chromatography-ion
8
chromatography-ion trap
8
trap mass
8
mass spectrometry
8
polycyclic aromatic
8
aromatic hydrocarbons
8
min lpgc-itms
8
conventional gc-ms
8
lpgc-itms
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!