The dose-response of Harshaw TLD-700H.

Radiat Prot Dosimetry

Thermo Electron Corporation, 26400 Broadway Avenue, Oakwood Village, OH 44146 USA.

Published: December 2006

Harshaw TLD-700H (7LiF:Mg,Cu,P) was previously characterised for low- to high-dose ranges from 1 microGy to 20 Gy. This paper describes the studies and results of dose-response and linearity at much higher doses. TLD-700H is a near perfect dosimetric material with near tissue equivalence, flat energy response, and the ability to measure beta, gamma and X rays. These new results extend the applicability of Harshaw TLD-700H into more dosimetric measurement environments. The simple glow curve structure provides insignificant fade, eliminating special oven preparation methods experienced by other materials. The work presented in this paper quantifies the performance of Harshaw TLD-700H in extended ranges.

Download full-text PDF

Source
http://dx.doi.org/10.1093/rpd/nci526DOI Listing

Publication Analysis

Top Keywords

harshaw tld-700h
16
tld-700h
5
dose-response harshaw
4
tld-700h harshaw
4
tld-700h 7lifmgcup
4
7lifmgcup characterised
4
characterised low-
4
low- high-dose
4
high-dose ranges
4
ranges microgy
4

Similar Publications

Background: Calibration of Thermo Luminescent Dosimetry (TLD) in eye lens dosimeter requires a standard phantom. The use of anthropomorphic phantoms in calibration needs evaluation.

Objective: This study aimed to analyze the angular response of the TLD on the fabricated 3D anthropomorphic head phantom and Computerized Imaging Reference Systems (CIRS)- Computed Tomography (CT) dose phantom as a standard phantom irradiated with Cs-137 and to compare the absorbed dose and linear attenuation for both phantoms.

View Article and Find Full Text PDF

The Health Protection Agency is changing from using detectors made from 7LiF:Mg,Ti in its photon/electron personal dosemeters, to 7LiF:Mg,Cu,P. Specifically, the Harshaw TLD-700H card is to be adopted. As a consequence of this change, the dosemeter holder is also being modified not only to accommodate the shape of the new card, but also to optimize the photon and electron response characteristics of the device.

View Article and Find Full Text PDF

Type testing of an extremity finger stall dosemeter based on Harshaw TLD EXTRAD technology.

Radiat Prot Dosimetry

July 2007

Health Protection Agency, Radiation Protection Division, Chilton, Didcot, Oxon, UK.

A new type of extremity dosemeter, which incorporates the Harshaw TLD EXTRAD dosemeter element into a PVC finger stall, has been developed. The dosemeter uses high-sensitivity lithium fluoride, (7)LiF:Mg,Cu,P (TLD-700H) in a thin 7 mg cm(-2) layer, with alternative coverings of PVC at 10 mg cm(-2) and aluminised polyester at 3.2 mg cm(-2).

View Article and Find Full Text PDF

Pre-irradiation and post-irradiation fading of the Harshaw 8841 TLD in different environmental conditions.

Radiat Prot Dosimetry

September 2008

Defence Science and Technology Laboratory, Alverstoke, Gosport PO12 2DL, UK.

The pre-irradiation and post-irradiation fading of a commercially available LiF:Mg,Cu,P thermoluminescent detector (TLD)-the Harshaw 8841 TLD-have been assessed. The Harshaw 8841 TLD comprises three TLD-700H chips (99.7% 7LiF and 0.

View Article and Find Full Text PDF

Type testing the Model 6600 plus automatic TLD reader.

Radiat Prot Dosimetry

December 2006

Thermo Electron Corporation, 26400 Broadway Avenue, Oakwood Village, OH 44146, USA.

The Harshaw Model 6600 Plus is a reader with a capacity for 200 TLD cards or 800 extremity cards. The new unit integrates more functionality, and significantly automates the QC and calibration process compared to the Model 6600. The Model 6600 Plus was tested against the IEC 61066 (1991-2012) procedures using Harshaw TLD-700H and TLD-600H, LiF:Mg,Cu,P based TLD Cards.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!