Objectives: We sought to describe the midterm results of extensive primary repair of the thoracic aorta by means of the modified elephant trunk technique with a stent graft for acute type A aortic dissection, particularly the changes of the false lumen shown by enhanced computed tomographic scanning.

Methods: The subjects were 35 consecutive patients who received arch replacement with open stent grafting for type A acute aortic dissection between December 1997 and April 2002. The mean follow-up period was 55 months (range, 30-83 months). Computed tomographic scanning was performed at 1, 3, 12, and 36 months postoperatively to detect thrombosis and obliteration of the false lumen after its exclusion by the stent graft. The diameter of the aorta was measured at 3 levels: the distal edge of the stent graft, the diaphragm, and the origin of the superior mesenteric artery.

Results: Two patients died in the initial operation, but no patients required additional surgical treatment of the thoracic aorta. The mean diameter of the stent grafts was 26.2 mm, and the mean length was 8.9 cm. Thrombus formation in the false lumen was recognized at the distal edge of the graft in all patients, at the diaphragmatic level in 26 patients, and at the superior mesenteric artery level in 15 patients. Obliteration of the false lumen was recognized at the distal edge of the graft in all patients, at the diaphragmatic level in 20 patients, and at the superior mesenteric artery level in 15 patients. The aorta distal to the stent graft showed minimal changes.

Conclusions: In patients with acute type A aortic dissections, it is possible to perform extensive primary repair of the thoracic aorta with relative safety by using a synthetic graft with a self-expanding stent, and this method might reduce the necessity of further operations not only for the distal descending aorta but also for the thoracoabdominal aorta.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jtcvs.2005.08.061DOI Listing

Publication Analysis

Top Keywords

stent graft
20
thoracic aorta
16
false lumen
16
level patients
16
extensive primary
12
primary repair
12
repair thoracic
12
acute type
12
type aortic
12
aortic dissection
12

Similar Publications

Long-term data are limited comparing percutaneous coronary intervention (PCI) with second-generation drug-eluting stents (S-DES) vs coronary artery bypass grafting (CABG) in patients with complex coronary artery disease (CAD). We aimed to conduct a systematic review and meta-analysis comparing these interventions in patients with left main or multivessel CAD. We systematically reviewed PubMed, Embase, and Cochrane for studies that compared PCI with S-DES and CABG in patients with left main or multivessel CAD with a minimum mean follow-up period of 3 years.

View Article and Find Full Text PDF

A 14-year-old boy developed hydronephrosis and worsening renal function due to fibroepithelial polyps of the bladder and left ureter at the age of 12 years. The endoscopic treatment of ureteral polyps was attempted by his previous doctor; however urethral stricture and ureteral stricture developed and was untreatable. Therefore, he was referred to our hospital for further reconstructive treatment.

View Article and Find Full Text PDF

Introduction: Coarctation of the aorta is a congenital narrowing of the thoracic aorta associated with hypertension and significant pressure gradients across the coarctation site. Coarctoplasty by percutaneous approach is the preferred method of treatment. However, complications like stent dislodgement may result and must be immediately managed to prevent adverse outcomes.

View Article and Find Full Text PDF

Background & Aim: The definition and clinical relevance of percutaneous coronary intervention (PCI)-related myocardial infarction (MI) has been a topic of significant debate and controversy. It has particularly garnered widespread attention recently due to a contemporary trend of including it as a component of primary end points in major trials. The study aimed to assess the clinical relevance of PCI-related MI (PMI) according to the Fourth Universal Definition of MI using a high-sensitivity troponin (hs-Tn) assay in a real-world setting.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?