Object: The aim of this study was to analyze the therapeutic decision-making process and outcome in 100 consecutive patients with aneurysmal subarachnoid hemorrhage (SAH) treated since the completion of the International Subarachnoid Aneurysm Trial (ISAT). All patients were evaluated and treated by a neurosurgeon with subspecialty training in both cerebrovascular and neuroendovascular surgery.

Methods: One hundred consecutive patients with aneurysmal SAH who had been admitted within 1 week posthemorrhage and who had been treated using either surgical clip application or endovascular coil embolization were included in this analysis. All patients underwent a uniform perioperative protocol. All surviving patients were given a questionnaire to assess their modified Rankin Scale score (mRS) and to grade themselves at 6 months and 1 year postintervention. The cohort consisted of 73 women and 27 men with a mean age of 57.27 years (range 27-87 years). Twenty-nine percent of the patients had a World Federation of Neurosurgical Societies (WFNS) Grade IV or V SAH. Forty-seven patients underwent direct surgical clip application, 41 endovascular embolization, and 12 a combination of the two procedures. Good functional outcome--indicated by mRS scores of 0 to 2 after at least 6 months--was achieved in 71% of patients.

Conclusions: Data from the ISAT demonstrated a better functional outcome following endovascular embolization in a selected group of patients with aneurysmal SAH. In routine clinical practice, however, a significant number of patients still benefit from direct surgical clip ligation. Excellent functional results can be realized in a complementary clip ligation and coil occlusion practice in which each patient and aneurysm is evaluated and the two treatment modalities are used individually or, when needed, in combination.

Download full-text PDF

Source
http://dx.doi.org/10.3171/jns.2006.104.3.344DOI Listing

Publication Analysis

Top Keywords

clip ligation
12
patients aneurysmal
12
surgical clip
12
patients
9
international subarachnoid
8
subarachnoid aneurysm
8
aneurysm trial
8
ligation coil
8
coil embolization
8
consecutive patients
8

Similar Publications

Introduction Lymphocele is a typical complication of pelvic lymph node dissection (PLND) in robot-assisted radical prostatectomy (RARP). This study aimed to compare postoperative lymphatic leakage between the polymer ligation clip and vessel sealer, and evaluated the costs associated with the former. Methods The study enrolled patients who underwent RARP with PLND at our institution between April 2018 and March 2023 and were treated with a vessel sealer (LigaSure Blunt Tip 44 NC; Medtronic, Dublin, Ireland) until September 2021, and Hem-o-lok polymer ligation clips(Teleflex, Wayne, PA, USA) thereafter.

View Article and Find Full Text PDF

Objective: In this study, changes in treatment methods and patient prognosis were analyzed using a Korean nationwide medical insurance information database.

Methods: Patients with subarachnoid hemorrhage who received surgical treatment for cerebral aneurysm from 2005 to 2020 were included. The specific surgery type was classified using the surgical code and according to whether stents were used.

View Article and Find Full Text PDF

Background: Gallbladder cancer is a rare disease with poor prognosis, for which surgical resection is considered the only curative treatment. The widespread adoption of laparoscopic cholecystectomy for benign biliary diseases has led to an increased incidence of postoperatively diagnosed gallbladder cancer. Several studies have proposed that tumors exceeding stage T2 require additional resection.

View Article and Find Full Text PDF

Structural optimization and in vitro corrosion analysis of biodegradable Mg-Nd-Zn-Zr alloy clip.

J Mech Behav Biomed Mater

January 2025

Shanghai Institute for Minimally Invasive Therapy, School of Health Science and Engineering, University of Shanghai for Science and Technology, 20093, China. Electronic address:

Article Synopsis
  • Magnesium (Mg) alloy clips offer a biodegradable option with good mechanical properties for use in hemostasis, but their deformation can lead to stress that increases corrosion rates.
  • Two designs of R-shape clips—one with staggered teeth and another with no teeth—were analyzed using finite element analysis and tested for corrosion and clamping performance.
  • Results showed that the staggered teeth clip had lower stress on blood vessels, better maintained structural integrity after clamping, and demonstrated higher pressure resistance, indicating strong potential for clinical use as biodegradable tissue clips.
View Article and Find Full Text PDF
Article Synopsis
  • - Hemorrhage is the main cause of preventable death in trauma situations, leading to military and civilian advancements in medical practices, particularly through the use of tourniquets to manage extremity bleeding and save lives.
  • - While tourniquets have significantly decreased deaths from bleeding in military settings, noncompressible hemorrhage still poses a major risk, especially before patients receive definitive medical care.
  • - The study explores using a small, disposable pressure monitor during resuscitative endovascular balloon occlusion of the aorta (REBOA) to enhance blood pressure monitoring, facilitate better resuscitation practices, and reduce the need for blood products in extreme environments.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!