Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Indications for implantable cardioverter defibrillator (ICD) implantation are expanding, but many primary and secondary ICD trials have excluded patients with advanced renal insufficiency. We investigated the effect of renal function on the incidence and time to first appropriate ICD shock.
Method: We analyzed data from all new ICD implantations at a tertiary care center from July 2001 to December 2002.
Results: During a mean follow-up time of 445 +/- 285 days, 29 (13%) of 230 patients (age 63 +/- 14 years, 79% men, 77% white, 75% coronary artery disease, left ventricular ejection fraction 0.28 +/- 0.14) received 41 appropriate shocks. Patients were divided into tertiles according to their serum creatinine level. The 1-year incidence of appropriate ICD shock was 3.8%, 10.8%, and 22.7% in the first, second, and third tertiles, respectively (P = .003). Using the same cut off values of serum creatinine, the 1-year incidence of appropriate ICD therapy (shock and antitachycardia pacing) was 8.8%, 20.8%, and 26.3% (P = .02). After correcting for age, sex, race, left ventricular ejection fraction, indication for ICD implantation, and use of beta-blockers in a Cox regression model, serum creatinine was still an independent predictor of the time to first appropriate ICD shock (hazard ratio 6.0 for the third compared with the first tertile, P = .001).
Conclusion: Renal insufficiency is a strong predictor of appropriate ICD shocks. Defibrillator therapy should therefore not be withheld based on the presence of this comorbidity. The mechanisms underlying the relationship between renal function and ventricular arrhythmias deserve further investigation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ahj.2005.06.042 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!