This study aimed at evaluating the effects of mechanical repositioning, obtained by the increase in seat-to-back (STB) and system tilt angles, on the position of the pelvis with spinal-cord injured subjects seated in a wheelchair. The noninvasive method used combined magnetic resonance imaging (MRI) images of the whole pelvis obtained in a supine posture and ultrasound images of the pelvic iliac crests obtained in four seating positions. The matching of the two image data sets enabled the location of fourteen pelvic landmarks in the seated positions. From these landmarks, the pelvic tilt, obliquity, and transverse rotation, and the three-dimensional (3-D) motion of the pelvis were calculated. Results showed that the increase in STB angle is not equal to the calculated increase in pelvic tilt and that the pelvis rotated posteriorly, moved forward and downwards. An increase in the system tilt moved the pelvis rearwards and downwards, which counter-balanced the movement seen with the increase in STB. At the return to the first position, no significant changes were observed in the pelvis' position and orientation compared to the initial posture. Results also demonstrated the importance in calculating the total 3-D rotations and translations to characterize adequately the pelvic movement.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/TNSRE.2006.870502 | DOI Listing |
J Orthop Surg Res
January 2025
Department of Medical Equipment, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan, China.
Background: Adolescent idiopathic scoliosis (AIS) is a complex three-dimensional deformity, and up to now, there has been no literature reporting the analysis of a large sample of X-ray imaging parameters based on artificial intelligence (AI) for it. This study is based on the accurate and rapid measurement of x-ray coronal imaging parameters in AIS patients by AI, to explore the differences and correlations, and to further investigate the risk factors in different groups, so as to provide a theoretical basis for the diagnosis and surgical treatment of AIS.
Methods: Retrospective analysis of 3192 patients aged 8-18 years who had a full-length orthopantomogram of the spine and were diagnosed with AIS at the First Affiliated Hospital of Zhengzhou University from January 2019 to March 2024.
Sci Rep
January 2025
Faculty of Mechanical Engineering, Wroclaw University of Science and Technology, K61 Łukasiewicza 7/9, Wrocław, 50-370, Poland.
The phenomenon of snaking of vehicles can be caused by many factors. It results from the loss of the vehicle's straight-line direction of motion, which is intended by the driver. In this situation, for single-mass vehicles (like automobiles), special systems (braking) are activated, aiming to return the vehicle to the direction intended by the driver.
View Article and Find Full Text PDFJpn J Ophthalmol
January 2025
Department of Neurology, Yokohama Brain and Spine Center, Yokohama, Japan.
Purpose: To assess the effects of modifying head position and of static ocular counter-rolling (OCR) on abduction and adduction in saccadic eye movements using a head-mounted video-oculographic device.
Study Design: A clinical observational study.
Methods: The peak velocities and amplitude gains of visually guided 12° saccades were binocularly measured in 21 healthy volunteers with their heads in the upright vertical (0°) and horizontal (± 90°, bilateral side-lying) postures, and in 6 participants with their head positions bilaterally tilted by 30°.
J Cell Biochem
January 2025
Bioinformatics Division I Microbiology Division, ICMR-Regional Medical Research Centre, Bhubaneswar, Odisha, India.
B0AT1 (SLC6A19) is a major sodium-coupled neutral amino acid transporter that relies on angiotensin converting enzyme 2 (ACE2) or collectrin for membrane trafficking. Despite its significant role in disorders associated with amino acid metabolism, there is a deficit of comprehensive structure-function understanding of B0AT1 in lipid environment. Herein, we have employed molecular dynamics (MD) simulations to explore the architectural characteristics of B0AT1 in two distinct environments: a simplified POPC bilayer and a complex lipid system replicating the native membrane composition.
View Article and Find Full Text PDFInsights Imaging
January 2025
Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
Objectives: To propose a reliable and standard 3D assessment method to analyze the effect of weight-bearing (WB) status on the location of patella and clarify the diagnostic performance of 3D parameters for recurrent patellar dislocation (RPD) in WB and non-weight-bearing (NWB) conditions.
Methods: Sixty-five knees of RPD patients and 99 knees of controls were included. Eight landmarks, two lines and a coordinate system were defined on 3D bone models of knees based on weight-bearing CT and non-weight-bearing CT.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!