A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Uncoupling the systemic circulation and the Ex Vivo circuit during experimental isolated liver perfusion. | LitMetric

Performing an ex vivo liver perfusion as a transient liver support requires perfusing the liver with a flow of 1 ml/min per kg of liver, which could reach 25% of the cardiac output when a human liver is used. This high flow could be detrimental in patients with acute liver failure. Therefore, in an ischemic-induced liver failure pig model, we developed a circuit allowing low flows going out of and into the systemic circulation, whereas the flow going through the ex vivo liver is maintained at a high value. This was obtained by uncoupling the ex vivo circuit from the systemic circulation. Ex vivo liver perfusion was performed in a closed circuit with a flow averaging 1 ml/min per kg of ex vivo liver (700 to 800 ml/min, according to the weight of the livers we used). It was linked to the systemic circulation with input and output flows equal to that used during hemodialysis (200 ml/min). Compared with previously reported direct circuits, this perfusion system was well tolerated from a circulatory point of view. After the induction of ischemic liver failure, the ex vivo liver perfusion led to an increase in urea, branched amino acids to aromatic amino acid ratio, and fractional clearance of indocyanine green and galactose and to a decrease in ammonia and lactic acid. This system allowed the ex vivo liver to keep its clearing properties despite a low extracorporeal flow. It represents an extracorporeal circuit that could be used in place of the direct extracorporeal high-flow liver perfusion.

Download full-text PDF

Source
http://dx.doi.org/10.1097/01.mat.0000203736.31150.4fDOI Listing

Publication Analysis

Top Keywords

vivo liver
24
liver perfusion
20
systemic circulation
16
liver
15
liver failure
12
vivo
8
circulation vivo
8
vivo circuit
8
perfusion
6
circuit
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!