Continuous-flow pumps are small, simple, and respond physiologically to input variations, making them potentially ideal for total heart replacement. However, the physiological effects of complete pulseless flow during long-term circulatory support without a cardiac interface or with complete cardiac exclusion have not been well studied. We evaluated the feasibility of dual continuous-flow pumps as a total artificial heart (TAH) in a chronic bovine model. Both ventricles of a 6-month-old Corriente crossbred calf were excised and sewing rings attached to the reinforced atrioventricular junctions. The inlet portions of 2 Jarvik 2000 pumps were positioned through their respective sewing rings at the mid-atrial level and the pulseless atrial reservoir connected end-to-end to the pulmonary artery and aorta. Pulseless systemic and pulmonary circulations were thereby achieved. Volume status was controlled, and systemic and pulmonary resistance were managed pharmacologically to keep mean arterial pressures at 100+/-10 mmHg (systemic) and 20+/-5 mmHg (pulmonary) and both left and right atrial pressures at 15+/-5 mmHg. The left pump speed was maintained at 14,000 rpm and its output autoregulated in response to variations in right pump flow, systemic and pulmonary pressures, fluid status, and activity level. Hemodynamics, end-organ function, and neurohormonal status remained normal. These results suggest the feasibility of using dual continuous-flow pumps as a TAH.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/01.mat.0000196827.61241.07 | DOI Listing |
Small
December 2024
State Key Laboratory of Materials-Oriented Chemical Engineering, College of Chemical Engineering, Nanjing Tech University, 30 Puzhu South Road, Nanjing, 211816, P. R. China.
Nanocarriers show great promise in drug delivery but face challenges in stability, uniformity, and morphology control. This work introduces an enhanced mixing process to overcome these obstacles, specifically aiming to produce consistently sized poly(lactic-co-glycolic) acid (PLGA) nanoparticles loaded with anti-tumor drugs. By innovatively integrating a pulsation dampener into the microfluidic channels of a continuous flow preparation system, the flow stability of piston pumps is improved nearly tenfold.
View Article and Find Full Text PDFArtif Organs
January 2025
Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA.
Background: The left atrial assist device (LAAD) is a novel continuous-flow pump designed to treat patients with heart failure with preserved ejection fraction, a growing type of heart failure, but with limited device-treatment options. The LAAD is implanted in the mitral plane and pumps blood from the left atrium into the left ventricle. The purpose of this study was to refine the initial design of the LAAD, using results from computational fluid dynamics (CFD) analyses to inform changes that could improve hydraulic performance and flow patterns within the LAAD.
View Article and Find Full Text PDFWaste Manag
December 2024
Anhui Province Tongyuan Environmental Environment Co., Ltd., China.
Landfills in developing countries are typically characterized by high waste water content and elevated leachate levels. Despite the ongoing biodegradation of waste in the highly saturated regions of these landfills, which leads to gas accumulation and bubble formation, the associated gas pressure that poses a risk to landfill stability is often overlooked. This paper introduces a landfill gas (LFG) bubble generation model and a two-fluid model that considers bubble buoyancy and porous medium resistance.
View Article and Find Full Text PDFLab Chip
September 2024
Imec, Life Sciences Technologies, Kapeldreef 75, 3001 Leuven, Belgium.
Applications such as nucleic acid synthesis or next-generation sequencing involve repeated fluidic cycles with the same set of reagents. The large dead volumes present in external valves and pumps with relatively long supply lines mandate the inclusion of extensive rinsing steps in current protocols, resulting in the consumption of significant quantities of reagents. To allow for fast rinsing, to reduce reagent consumption, and to ensure high reagent purity, we propose a fluidic concept based on a hierarchical branching structure.
View Article and Find Full Text PDFDiabetes and post-transplant survival have been linked. However, the impact on post-transplant survival of patients supported on Continuous Flow (CF) axial left ventricular assist devices (LVAD) as a bridge to transplant (BTT) with diabetes has not been widely studied. This study attempts to assess the impact of diabetes type II (DM type II) as a comorbidity influencing survival patterns in the post-cardiac transplant population supported on LVADs and to test if the presence of a pre- transplant durable LVAD acts as an independent risk factor in long-term post-transplant survival.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!