Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To compare the effect of reduced exposure times on the microhardness of resin composites cured with a "second-generation" light-emitting diode (LED) curing light and a quartz-tungsten-halogen (QTH) curing light.
Methods: Ten composites were cured with a LED curing light for 50% of the manufacturers" recommended exposure time or a QTH light at the high power setting for 50% of the recommended time or on the medium power setting for 100% of the recommended time. The composites were packed into Class I preparations in extracted human molar teeth and cured at distances of 2 or 9 mm from the light guide. The moulds were separated, and the Knoop microhardness of the composites was measured down to 3.5 mm from the surface.
Results: The LED light delivered the greatest irradiance at 0 and 2 mm, whereas the QTH light on the standard (high power) setting delivered the highest irradiance at 9 mm. According to distribution-free multiple comparisons of the hardness values, at 2 mm from the light guide the LED light (50% exposure time) was ranked better than or equivalent to the QTH light on the high power setting (50% exposure time) or on the medium power setting (100% exposure time). At 9 mm, the LED light was ranked better than or equivalent to the QTH light (both settings) to a depth of 1.5 mm, beyond which composites irradiated by the LED light were softer (p < 0.01). At both distances, the QTH light operated on the high power setting for 50% of the recommended exposure time produced composites that were as hard as when they were exposed on the medium power setting for 100% of the recommended exposure time.
Conclusions: The ability to reduce exposure times with high-power LED or QTH lights may improve clinical time management.