A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effect of reduced exposure times on the microhardness of 10 resin composites cured by high-power LED and QTH curing lights. | LitMetric

Purpose: To compare the effect of reduced exposure times on the microhardness of resin composites cured with a "second-generation" light-emitting diode (LED) curing light and a quartz-tungsten-halogen (QTH) curing light.

Methods: Ten composites were cured with a LED curing light for 50% of the manufacturers" recommended exposure time or a QTH light at the high power setting for 50% of the recommended time or on the medium power setting for 100% of the recommended time. The composites were packed into Class I preparations in extracted human molar teeth and cured at distances of 2 or 9 mm from the light guide. The moulds were separated, and the Knoop microhardness of the composites was measured down to 3.5 mm from the surface.

Results: The LED light delivered the greatest irradiance at 0 and 2 mm, whereas the QTH light on the standard (high power) setting delivered the highest irradiance at 9 mm. According to distribution-free multiple comparisons of the hardness values, at 2 mm from the light guide the LED light (50% exposure time) was ranked better than or equivalent to the QTH light on the high power setting (50% exposure time) or on the medium power setting (100% exposure time). At 9 mm, the LED light was ranked better than or equivalent to the QTH light (both settings) to a depth of 1.5 mm, beyond which composites irradiated by the LED light were softer (p < 0.01). At both distances, the QTH light operated on the high power setting for 50% of the recommended exposure time produced composites that were as hard as when they were exposed on the medium power setting for 100% of the recommended exposure time.

Conclusions: The ability to reduce exposure times with high-power LED or QTH lights may improve clinical time management.

Download full-text PDF

Source

Publication Analysis

Top Keywords

power setting
28
exposure time
20
qth light
20
high power
16
led light
16
light
13
exposure times
12
composites cured
12
recommended exposure
12
setting 50%
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!