Background: The aim of this study was to investigate the adsorption of local anesthetics lidocaine and ropivacaine, into disposable infusion balloons made from various kinds of plastics.

Methods: The concentration of local anesthetic that flows out of a balloon was measured.

Results: The concentration of both lidocaine and ropivacaine in clinical formula decreased only 4.5 percent regardless of infusion balloons. However, the concentration of lidocaine pH 7.4 decreased by 10 percent in the Syrinjector made from polypropylene and polyvinyl chloride, and that of 18-20 percent in other infusion balloons (Surefuser, Baxtor Infuser, DIB Catheter made from isoprene rubber and polyvinyl chloride, isoprene rubber and polyvinyl chloride, silicon and polyvinyl chloride, respectively).

Conclusions: The adsorption of local anesthetic into infusion balloons has little effect in clinical situation. Whereas, in case of lidocaine pH 7.4, the adsorption depends on the specific type of plastics.

Download full-text PDF

Source

Publication Analysis

Top Keywords

infusion balloons
16
polyvinyl chloride
16
local anesthetic
12
disposable infusion
8
adsorption local
8
lidocaine ropivacaine
8
concentration lidocaine
8
decreased percent
8
percent infusion
8
isoprene rubber
8

Similar Publications

Restenosis remains a long-standing limitation to effectively maintain functional blood flow after percutaneous transluminal angioplasty (PTA). While the use of drug-coated balloons (DCBs) containing antiproliferative drugs has improved patient outcomes, limited tissue transfer and poor therapeutic targeting capabilities contribute to off-target cytotoxicity, precluding adequate endothelial repair. In this work, a DCB system was designed and tested to achieve defined arterial delivery of an antirestenosis therapeutic candidate, cadherin-2 (N-cadherin) mimetic peptides (NCad), shown to selectively inhibit smooth muscle cell migration and limit intimal thickening in early animal PTA models.

View Article and Find Full Text PDF

Background: Coronary stenting operations have become the main option for the treatment of coronary heart disease. Vessel recovery after stenting has emerged as a critical factor in reducing possible complications. In this study, we evaluated the feasibility, safety and efficacy of locally administered intraluminal gene therapy delivered using a specialized infusion balloon catheter.

View Article and Find Full Text PDF

Tugging the Foley Catheter Balloon Every Three Hours in Induction of Labor After One Previous Cesarean: A Randomized Controlled Trial.

Am J Obstet Gynecol MFM

December 2024

Department of Obstetrics and Gynecology, Faculty of Medicine, Universiti Malaya, Jalan Profesor Diraja Ungku Aziz, 50603, Kuala Lumpur, Malaysia. Electronic address:

Article Synopsis
  • Induction of labor after a previous cesarean poses high risks, and using a Foley balloon for mechanical ripening is preferred over prostaglandins due to lower risk of complications like uterine rupture.
  • This study aims to assess the effects of tugging the Foley balloon every three hours on the time from induction to delivery and overall patient satisfaction compared to standard care without tugging.
  • Conducted as a randomized controlled trial in Malaysia from April 2023 to March 2024, 126 participants were recruited, and outcomes measured included the time interval from balloon insertion to delivery and participants' satisfaction, with expectations of a significant reduction in delivery time and improvement in satisfaction scores.
View Article and Find Full Text PDF
Article Synopsis
  • A 44-year-old man experienced a severe allergic reaction after receiving SonoVue during a heart test, leading to chest pain and a heart attack caused by stent thrombosis and coronary vasospasm.
  • Treatment involved mechanical thrombectomy, stent replacement, and careful management to avoid worsening the patient's condition, ultimately resulting in his recovery and discharge with normal heart function.
View Article and Find Full Text PDF

The Need for Preoperative Prostaglandin E1 for d-Transposition After Balloon Atrial Septostomy.

CJC Pediatr Congenit Heart Dis

October 2024

Division of Cardiology, Faculty of Pediatrics, University of British Columbia, Vancouver, British Columbia, Canada.

Article Synopsis
  • The study investigates the controversial role of prostaglandin E1 (PGE) in infants with d-transposition of the great arteries (dTGA) undergoing arterial switch operation (ASO) following balloon atrial septostomy (BAS).
  • Out of 35 dTGA cases reviewed, 65% required PGE infusion, with a significant 60% of these infants needing PGE to be restarted after initially stopping.
  • The findings suggest that keeping PGE until oxygen saturation reaches at least 80% may lower the risk of rebound hypoxia, without increasing adverse effects from the medication.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!