Objective: Inhibition of fibrin sheath formation by enoxaparin decreases catheter colonization. Fibrin-binding radioactive tracer and catheter weights quantify fibrin reduction.

Design: Controlled experimental study of central venous line colonization.

Setting: Animal laboratory.

Subjects: Adult male Sprague-Dawley rats.

Interventions: Central venous lines were introduced into right external jugular veins of 254 animals in three groups: enoxaparin, Fibrimage, and catheter weight. The enoxaparin group (n = 196) received daily enoxaparin injections (n = 97) or catheter implantation only (n = 99); 176 received tail vein injections of Staphylococcus epidermidis on postoperative day (POD) 10. Twenty rats received saline injections as a control. On POD 13, catheters were removed and incubated in broth at 37 degrees C for 48 hrs. Turbid samples were plated. In the Fibrimage group (n = 39), 20 rats receiving enoxaparin were compared with 19 controls without enoxaparin; all received S. epidermidis injections on POD 10. Fibrimage, fibrin-binding radiolabeled tracer, was given 1 hr before catheter removal. In the weight group (n = 19), six rats received enoxaparin; 13 did not. All received injections of S. epidermidis on POD 10.

Measurements And Main Results: Positive plates underwent analytic profile index testing, ensuring correlation with inoculum. Results were compared using Fisher's exact or chi-square tests. Gamma counts were determined in the Fibrimage group. Catheter tip weights were recorded. Results from the Fibrimage and weight groups were compared using Student's t-test. The enoxaparin group had fewer catheters colonized (17 of 77) vs. no enoxaparin (42 of 99; p < .01). Pericatheter sheaths contained less fibrin compared with controls. Fibrimage group gamma counts were significantly decreased for the enoxaparin subgroup (x = 2244 counts per minute) vs. controls (x = 3767 counts per minute; p < .0002). The weight of catheter tips treated with enoxaparin (x = 39 mg) vs. controls (x = 90 mg) was also significantly decreased (p < .0001).

Conclusions: Enoxaparin decreases the amount of fibrin surrounding central venous catheters. The incidence of catheter colonization decreases when the amount of fibrin within the pericatheter sheath decreases.

Download full-text PDF

Source
http://dx.doi.org/10.1097/01.CCM.0000215832.40827.71DOI Listing

Publication Analysis

Top Keywords

central venous
16
enoxaparin
13
catheter colonization
12
fibrimage group
12
catheter
9
fibrin sheath
8
sheath formation
8
enoxaparin decreases
8
tracer catheter
8
catheter weights
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!