The authors studied the concordance among seven pathologists for the histologic diagnosis, interpretation of KIT immunostaining, and determining MIB-1 labeling indices (LI) in 80 adult patients with primary spindle cell tumors, mainly of the gastrointestinal tract, mesentery, retroperitoneum, and pelvis, based on the review of tissue sections using an immunohistochemical panel of antibodies for KIT/CD117, CD34, desmin, smooth muscle actin (SMA), and S-100 protein. Tumors included 30 gastrointestinal stromal tumors (GISTs), 10 leiomyomas, 10 leiomyosarcomas, 10 schwannomas, 10 solitary fibrous tumors, and 10 desmoid-type fibromatoses. The overall concordance with the original diagnosis of each histologic type was 97.9%, the kappa value ranging from 0.95 to 1.00 (mean 0.97), indicating a perfect agreement. The overall interlaboratory concordance with the original interpretation of KIT immunostaining was 91.3%, the kappa value ranging from 0.77 to 0.90 (mean 0.86). The overall interlaboratory concordance with the original interpretation of KIT immunostaining was 91.9%, the kappa value ranging from 0.72 to 0.93 (mean 0.85). The overall concordance for determining MIB-1 LI was 90% with the original evaluation, and the overall kappa value ranged from 0.62 to 0.86 (mean 0.77). These results indicate that it is possible to reliably diagnose GIST and other spindle cell tumors of the gastrointestinal tract with the use of an immunohistochemical panel of antibodies for KIT, CD34, desmin, SMA, and S-100 protein. Although there is clearly unavoidable inter-observer and interlaboratory variability in the interpretation of KIT immunostained sections and interobserver variability in the determination of MIB-1 LI, the concordance between observes is very acceptable, and in most instances such variability can be eliminated by careful reviewing of the hematoxylin and eosin and immunostained sections.

Download full-text PDF

Source
http://dx.doi.org/10.1097/01.pai.0000151023.88969.d7DOI Listing

Publication Analysis

Top Keywords

interpretation kit
20
kit immunostaining
16
determining mib-1
12
spindle cell
12
cell tumors
12
tumors gastrointestinal
12
gastrointestinal tract
12
concordance original
12
kappa ranging
12
interobserver variability
8

Similar Publications

In this study, a novel rapid immunochromatographic (IC) test for African swine fever virus (ASFV) antibodies is presented. An immunochromatographic test (IC) is a detection technique that combines membrane chromatography with immunolabeling. This approach saves time for antibody preparation, resulting in a shorter production cycle.

View Article and Find Full Text PDF

Spinal muscular atrophy (SMA) is a degenerative neuromuscular condition resulting from a homozygous deletion of the survival motor neuron 1 () gene in 95% of patients. A timely diagnosis via newborn screening (NBS) and initiating treatment before the onset of symptoms are critical for improving health outcomes in affected individuals. We carried out a screening test by quantitative PCR (qPCR) to amplify the exon seven of using dried blood spot (DBS) samples.

View Article and Find Full Text PDF

Screening for inborn metabolic disorders (IMDs) in newborns is an important way to prevent serious metabolic and developmental difficulties that can result in lasting disabilities or even death. Electrospray ionization tandem mass spectrometry (MS/MS) provides an efficacious newborn blood spot screening (NBS) mechanism for analyzing dried blood spot specimens (DBSs) for biochemical markers for these conditions. Where possible, the elimination of derivatization in specimen preparation can simplify and streamline analysis.

View Article and Find Full Text PDF

Background Objectives: Co-infection of dengue virus and acute hepatitis A virus in paediatric population is a major health concern in endemic countries. This cross sectional retrospective study was conducted to evaluate the prevalence of hepatitis A virus among the clinically dengue suspected paediatric cases presented at our tertiary care centre during the two-year period (2022-2023).

Methods: A total of 747 dengue suspected paediatric clinical specimens were included in this study.

View Article and Find Full Text PDF

Establishing Decisional Cutoff Values of Neurofilament Light Chains in Cerebrospinal Fluid Measured by Fully Automated Chemiluminescent Enzyme Immunoassay.

J Clin Lab Anal

January 2025

Department of Biomedicine, Neurosciences and Advanced Diagnostics, Institute of Clinical Biochemistry, Clinical Molecular Medicine, and Clinical Laboratory Medicine, University of Palermo, Palermo, Italy.

Introduction: Neurofilament light chain (NfL) is one of the most important biomarkers in the field of clinical neurochemistry. Several analytical methods have been developed in the last decade. Recently, Fujirebio introduced a ready-to-use assay kit for measuring NfL levels in the cerebrospinal fluid (CSF) on the fully automated LUMIPULSE G System.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!